The sealing performance of ball valves is a key indicator of ball valve quality. Therefore, the research on the sealing structure of cryogenic ball valves has always been the focus and hot spot in this field.

- LNG cryogenic shut-off valves, which shut off or start the flow of media.
- LNG cryogenic check valves, which prevent backflow of media.
- LNG cryogenic pressure regulating valves (pressure reducing valves), which regulate the pressure within the storage tank.
- LNG cryogenic safety valves, which provide overpressure protection.
- LNG cryogenic pneumatic emergency shut-off valves are used in the event of a disaster.
US standards require that LNG be treated with gasoline-grade fire and explosion retardants. Furthermore, the cryogenic nature of LNG, when leaked, creates a large vapor cloud, making LNG even more dangerous.
The Difference Between LNG Cryogenic Valves and LO2, LN2, and LAr Cryogenic Valves
| Methane (LNG) | Liquid nitrogen (LNz) | Liquid oxygen (LOz) |
| Various aluminum alloys | Austenitic nickel alloy stainless steel | Aluminum and aluminum alloys |
| 9% nickel alloy (ASTM-A353) | Type 18-8 stainless steel | Stainless steels 304, 316, 304L, 310, 312, 304ELC |
| Type 304 stainless steel (ASTM-A240) | Copper, brass, bronze | 9% nickel alloys |
| Other materials have proven satisfactory with liquid methane | Nickel steel (9%) silicon brass | Copper and copper alloys |
| Monel, aluminum, titanium door V | Nickel and nickel alloy presses |
The table above indicates that copper and copper alloys are not recommended for use in LNG-fueled equipment. The NFPA 1996 standard, NFPA 57, states in Section 2-2.4: “All materials selected or installed shall be protected from corrosion to the greatest extent possible. “2-2.5 All brazing fillers have a melting point exceeding 1000°F (538°C).” However, copper and copper alloys are used extensively in LO2, LN2, and LAr cryogenic valves, while 304 stainless steel is currently used in LNG cryogenic valves.

Due to the ignition and explosive nature of LNG, LNG cryogenic valves require higher technical performance and requirements. In design, the primary consideration is that the valve’s main components must be able to withstand the thermal stresses caused by sustained or transient large temperature fluctuations. Material capacity is a key factor.