Gas stations use a comprehensive loss calculation formula: Comprehensive Loss = Beginning Inventory + Current Period Intake – Current Period Sales – Ending Inventory. When any of these parameters is inaccurate, false losses or surpluses occur. There are two main reasons for false losses:
- Fuel temperature at the time of intake.
- Inaccurate tank capacity tables.

False Losses Caused
Gas stations use a pump-in/pump-out metering system; if the fuel temperature at the depot is high, while the fuel temperature is low, the fuel volume will shrink during sales, resulting in false losses. How much loss will this cause?
- Vt2 = Vt1[1 + f(t2 – t1)]
Volume expansion coefficient of the fuel, typically 0.0012/°C for gasoline and 0.0008/°C for diesel. The coefficient of thermal expansion shows that diesel is less affected by temperature than gasoline.
For example, if an oil depot dispenses 10,000L of diesel at a temperature of 32°C, and the gas station sells it at 28°C, ignoring other losses.
- V2 = 10,000[1 + 0.0012(28 – 32)] = 9952L.
The gas station should not bear this loss; otherwise, the excessive false loss would make it impossible to implement corresponding management measures and performance evaluations.
This is because current fuel dispensers lack temperature-compensation functions, and the state has not stipulated a unified temperature for measurement.
False losses during inventory due to inaccurate tank volume tables
Inaccurate tank volume tables, or tilting or deformation of tanks after burial, will cause inaccurate inventory data. Especially when tilted, a very large measurement error will occur. Taking a 50m3 horizontal tank as an example, when the oil level is 40%-60% of the diameter, 0.6% can result in a calculated error of 400-500L. We have a comprehensive loss formula:
- Comprehensive Loss = Beginning Inventory + Current Period Intake – Current Period Sales – Ending Inventory
When the volume meter is inaccurate or the tank is tilted, errors will be introduced.
- Comprehensive Loss = (Beginning Inventory – Δ1) + Current Period Intake – Current Period Sales – (Ending Inventory – Δ2) = Current Period Loss – (Δ1 – Δ2)

BLUESKY has designed a tank calibration system combining its high-precision fuel dispensers, level gauges, and gas station management. A certain drop height is taken as the measurement interval so that the drop height corresponds one-to-one with the sales volume. The oil tank volume table calculation software can be developed, which can easily mark the oil tank volume table.