The solenoid valve is an essential component of a fuel dispenser. During preset refueling, the main valve closes before the preset value is reached. Furthermore, the special design of the pressure-relief orifice and damping orifices in the solenoid valve allows the diaphragm to close smoothly, avoiding the impact of direct closure. This solves the problems of pipe cracking, flow meter damage, and a sudden decrease in seal life caused by oil pressure shock in the pipeline during shutdown. Let’s take a look at the structure of a solenoid valve.
1. Solenoid Valve Structure
1.1 External Structure

- 1-Lower chamber: Oil inlet chamber
- 2-Diaphragm: Divides the valve body into upper and lower chambers
- 3-Upper chamber: Control chamber
- 4-Small pilot valve chamber: Controls the small flow channel
- 5-Large pilot valve chamber: Controls the main valve (large flow)
- 6-Solenoid valve coil
1.2 Internal Structure
The diagram above shows the lower chamber of the solenoid valve body.

- 1 is the oil inlet
- 2 is the oil outlet, and 6 is the diaphragm. The diaphragm isolates the oil inlet and outlet.
- 3 The bottom of the small hole connects to the oil inlet, and the outlet connects to the small pilot valve chamber.
- 4 The bottom of the small hole connects to the oil outlet, and the outlet connects to the small pilot valve.
- 5 The bottom of the small hole connects to the oil outlet, and the outlet connects to the large pilot valve.
- 7 are the fixing screw holes for the upper and lower chamber valve bodies, numbered 4.

The diagram above shows the upper chamber of the solenoid valve body. The small pilot valve chamber, large pilot valve chamber, and upper chamber are a single unit.
- 1 is a through-hole between the small pilot valve chamber and the upper chamber, serving as a pressure relief and pressure replenishment function.
- 2 is a through-hole between the large pilot valve chamber and the upper chamber, serving only as a pressure relief function, numbered 2.
- 3 is a small hole connecting the small pilot valve to the oil inlet.
- 4 is a small hole connecting the small pilot valve chamber to the oil outlet.
- 5 is a small hole connecting the large pilot valve chamber to the oil outlet.
1.3 Valve Core Structure

- Coil: When energized, it attracts the valve core to move upward against the spring force, opening the passage to the oil outlet.
- Valve Core: The switch that controls whether the large and small pilot valve chambers are connected to the oil outlet.
- Spring: Provides a certain pressure to the valve core.
2. Principle of Solenoid Valve Opening
2.1 Fully Closed State (Coils De-energized)
- Both the large and small pilot valves are closed.
- Diaphragm Upper Chamber: There are two paths connecting it to the oil inlet chamber: one is through the diaphragm damping orifice 1, and the other is through the small orifice 2 in the small pilot valve chamber. Thus, the pressure in the upper chamber equals the inlet pressure.
- Pressure balance on the upper and lower diaphragm + spring pressure → main valve (large valve) is tightly closed, and the small flow channel is also blocked by the small pilot valve → no flow.

1- is the damping orifice. 2- is the orifice from the small pilot valve chamber to the upper chamber.
2.2 Only the small valve is open (small coil is energized, large coil is de-energized)
- The small pilot valve opens, and the large pilot valve closes.
- Oil flows from the inlet (1 in the left diagram) → small flow channel (3) → small pilot valve chamber → oil outlet 4.
Features: The flow rate is very low (approximately 1/10 of the large flow rate), and the main valve remains closed.

2.3 Both valves are fully open (both coils are energized)
The small pilot valve and the large pilot valve open simultaneously
- The upper chamber depressurizes very quickly, and the lower chamber is under high pressure from the inlet → a pressure difference is formed between the upper and lower parts of the diaphragm.
- The pressure difference overcomes the spring force → the diaphragm rises → the main valve (large valve) is fully open.
- The oil is divided into two paths: the large flow channel of the main valve + the small flow channel → the maximum flow rate of oil is added.
2.4 Approaching Quantity: Close the Main Valve, Leave the Small Valve Open (Crucial!)
1) When the fuel dispenser is approaching the set value (generally 0.3-0.4 L remaining):
Large coil de-energized → Large pilot valve closed
Small coil energized → Small pilot valve remained open
2) Diaphragm Upper Chamber: Pressure can only be slowly replenished through the diaphragm damping orifice → Pressure difference disappears → Spring presses down the diaphragm → Main valve closes, leaving only a small flow channel to continue dispensing fuel → Slow and precise dispensing to correct the “overshoot”.
2.5 Reaching Quantity: Fully Closed
Small coil de-energized → Small pilot valve closed → Complete fuel cut-off.
The above is the entire process of the solenoid valve’s operation.