With the widespread application of liquefied natural gas (LNG) as an automobile fuel, the design of the LNG dispenser has become crucial.

Key points of LNG dispenser design
Basic structural design
The HG series LNG dispenser produced by our company is composed of casing, computer controller, pressure sensor, explosion-proof junction box, stop valve, safety valve, emergency shut-off valve, mass flow meter, solenoid valve, check valve, filling hose, return hose, break valve, filling gun seat, filling gun head and seamless stainless steel pipe and stainless steel joint. The casing should have good protective performance to protect the internal components from the influence of the external environment. The computer controller adopts a high-performance industrial control microprocessor chip to ensure high stability under a harsh working environment. The electrical part adopts an explosion-proof and sealed structure to adapt to the explosive environment of the gas station.
Liquid filling process design
Liquefied natural gas is transported into the gas dispenser through the submersible pump skid, and flows through the inlet stop valve, safety valve, mass flow meter, solenoid valve, check valve, liquid filling hose, liquid filling gun head, and finally flows into the car’s onboard bottle. The mass flow meter is responsible for measuring the density, mass, and other parameters of the gas flowing through the gas dispenser, and displays the collected mass, temperature, density, and other signals to the user through the display screen, thereby completing a liquid filling metering process.

Matters needing attention in the design of the LNG dispenser
Design parameters
Pressure design:
The pressure design of the LNG filling pipeline should be 1.2 times the pressure generated during its filling work. The pressure of the LNG filling pipeline mainly comes from the gas phase pressure of the storage tank and the head of the LNG submersible pump. The sum of the two is the pressure of the LNG filling pipeline when it is working. The design pressure of the liquid dispenser is usually 2.0MPa, and the maximum working pressure is 1.6MPa.
Temperature factor:
LNG is a cryogenic liquid. During its transportation process, it will continuously absorb the surrounding heat, thereby producing evaporated natural gas. Therefore, when designing the pipeline of the liquid filling machine, attention should be paid to the insulation design of the low-temperature pipeline, and vacuum tubes should be used as much as possible to promote the stable transportation of LNG and prevent evaporation. In addition, it is also necessary to consider that the residual water in the pipeline will freeze under the influence of factors such as low temperature, which will lead to the blockage of the valve, and the residual liquid in the liquid filling gun after liquid filling will freeze and freeze the sealing ring, causing the liquid filling gun to leak.
Safety design
LNG is flammable, easy to evaporate, easy to spread, and explosive, so the LNG liquid filling machine is in a dangerous area. During the design process, it is necessary to design dangerous area signs such as fire, and set up corresponding fire extinguishers and other fire-fighting facilities according to the gas filling level designed for the LNG filling station and the scale of the LNG gas storage tank. The explosion-proof structure design of the electrical part must strictly comply with relevant standards to prevent electrical sparks from causing explosion accidents. And at the gas filling machine, an anti-static release device is installed, and a gas alarm device is installed on the liquid filling machine, so that the filling can be stopped immediately when a leak occurs to ensure safety.

3. Conclusion
The design of an LNG dispenser is a complex system engineering, which requires comprehensive consideration of multiple factors. In the design process, full attention should be paid to key issues such as design parameters, fire safety, reliability, and maintainability to ensure the safe, stable, and accurate operation of the dispenser and provide strong support for the development of liquefied natural gas vehicles. With the continuous advancement of technology and the continuous improvement of application needs, the design of LNG dispensers also needs to be continuously innovated and improved.