The First Container CNG Daughter Station in Enugu, Nigeria, was manufactured by Bluesky.

The detailed information we provide for customer
The whole Container CNG Daughter Station already includes the main equipment necessary for a CNG daughter station to run normally.
The whole system is with the following details :
- CNG offloading discharge port. The mass flowmeter calculates the CNG offloading amount from the CNG tube trailer.
- CNG Compressor System: Two-stage CNG daughter station compressor which flowrate around 1200 Nm3/hour. The min inlet pressure requirement is around 50 bar. Could achieve the pressurizing CNG
- CNG Cylinder Group: These 36 pcs 180 L CNG cylinder group groups our buffer storage area. That could stock around 1300 Nm3 CNG under 200 bar pressure. Could used for refilling directly.
- CNG Refilling Dispenser: B with mass flowmeter, be with CNG refilling nozzle. That fits for most CNG Vehicles in the market.
- PLC Control and Alarm Syste: The entire system can be intelligently controlled by PLC, and the parameters can be set according to the actual site needs so that the entire compressor system can automatically start and stop according to the set parameters. The pressure, current, and status data monitoring required by all sites are integrated into one system for easy operation and viewing.

The after-sale service provided by Bluesky
Installation Guidance:
During the delivery period, the Blue Sky team planned the basic facilities construction according to the customer’s actual application scenarios and products, but the customer did not complete it according to the initial requirements. After the team arrived, they found that the entire site was not suitable for the operation of the Container CNG Station.
There are certain site application requirements for the Container CNG daughter station:
1. Solid, stable, and horizontal ground. The CNG compressor will be accompanied by very slight vibration during operation, so the equipment needs to be fixed on the horizontal ground to prevent displacement or sliding.

2. Stable and compliant current and voltage supply requirements. The CNG compressor relies on the motor to start. Too high or too low voltage will affect the equipment. If the current is insufficient, the CNG compressor cannot start, causing the entire system to fail to work.
3. Sufficient space. The main gas source of the CNG daughter station comes from CNG tank trucks, so there needs to be enough space near the container for tank trucks to park, and the filling area also needs to have enough space for the front of the truck to park.
The original intention of our design of the Container CNG daughter station is to save customers time in infrastructure construction. The entire construction period of the customer is completed within 7 days. After being equipped with corresponding power equipment, the entire equipment can be tested for operation.
Testing:
The container CNG daughter station is operated in a high-pressure environment as a whole, so engineers with certain experience are required to check before the overall operation to ensure that there is no leakage in the pipelines and joints and check whether the entire system is damaged or loose during transportation.

Soft start test circuit, test whether the power environment is stable, and prevent excessive voltage from damaging the CNG compressor motor.
Air internal circulation pressurization test, test whether there is leakage in CNG cylinders and valves, and test whether the pressure detection is normal.

Training:
Teach customers how to use and operate the system correctly, the precautions of the entire CNG Daughter Station, and also provide training on gasoline vehicle oil conversion.