Common faults of fuel dispensers

Today, let’s take a look at common faults of fuel dispensers:

RT-HG new design fuel dispenser

Composition of fuel dispensers

1. Composition of self-priming fuel dispensers Self-priming dispensers are mainly composed of an explosion-proof motor, self-priming pump, explosion-proof junction box, power supply device, flow meter, solenoid valve, oil gun, switch, sensor, computer device, display screen, keyboard, and anti-cheating device.

2. Composition of submersible pump fuel dispensers Submersible pump dispensers are mainly composed of a submersible pump control box, explosion-proof junction box, power supply device, flow meter, solenoid valve, oil gun, switch, sensor, computer device, display screen, keyboard, and anti-cheating device.

fuel pump2

Common faults of oil pumps

1. Reasons for high vibration and noise:
  •  Pipeline: is too long, has too many bends, too dirty.
  • Overflow valve: The spring is adjusted too tight, and the valve core is stuck by foreign objects and cannot be opened.
  • Blades and springs are broken and stuck
  •  Resonance occurs inside the machine
  • The viscosity of the oil is too low and the lubricity is poor.
2. Reasons for lack of oil supply or insufficient oil supply:
  • Check the motor (no rotation, reverse rotation, low speed), and V-belt (too loose, aging)
  •  Check the overflow valve: foreign matter is stuck, the overflow valve is in a normally open or half-open state, and high pressure cannot be formed in the pump chamber
  • Check the blades or springs: the blades are severely worn, and inflexible in the rotor slot, and the spring is broken, so that the blades cannot pop out, making the vacuum degree of the pump not meet the requirements.
  • The rotor is stuck, causing the pump shaft and the rotor to fall off, and the pump shaft cannot absorb oil when idling.
3. Causes of leakage:
  • Blade wear, spring sheet breakage, etc. may cause increased internal leakage
  • External leakage at the root of the pump shaft is mostly caused by failure of the skeleton oil seal
  • The sealing ring or gasket at the joint surface between the pump cover and the pump body, the joint surface between the pump body and the oil-gas separator, and the overflow valve cover nut are damaged
Gear pump failures also include: momentary pause
  • A Dirty filter
  • High oil temperature
  • There is gas in the pump

Oil-gas separator:

The oil in the underground oil tank is sucked by the oil pump, first sucked into the low-pressure chamber of the separator through the oil pump, and then sucked into the pump. The pump delivers high-pressure oil to the high-pressure chamber of the separator.

Common faults of oil-gas separator

1. Oil and gas cannot be separated
  • The air outlet valve fails (blocked).
  • The outlet valve fails. It is in the normally open state so that the air in the high-pressure chamber cannot be discharged from the air outlet hole at once.
2. Large vibration and noise
  • The filter is too dirty
  • The outlet valve is stuck and cannot be opened
3. No oiling
  • The outlet valve is stuck or rusted
  • The float cannot return to its original position after floating up, resulting in air circulation without oiling
  • The high-pressure chamber is connected to the low-pressure chamber, resulting in internal leakage, the high-pressure chamber cannot form high pressure, and the outlet valve cannot be opened.
4. Exhaust pipe spitting oil
  • The float cannot float due to deformation, rust, damage, etc., and the oil in the normal-pressure chamber cannot return to the low-pressure chamber. When the oil is full, it will be discharged from the exhaust pipe.
  • The parallel valve fails and cannot be opened.
  • The exhaust valve fails (when the float cannot float, the exhaust valve cannot be closed or is not closed tightly)
  • The diameter of the 1.2mm damping hole is too large so too much oil enters the float chamber. The float has no time to leak, and the excess oil is discharged through the exhaust pipe.
  • The machine is turned on many times without oiling.

Sensor:

Use photoelectric conversion devices to convert the angular displacement of the flowmeter transmission shaft into the number of electrical pulses, that is, together with the flowmeter, the output oil volume is converted into the number of electrical pulses for the computer device to calculate, store and display.

Tatsuno flowmeter

Flowmeter:

Measure the output oil volume and convert the output oil volume into the angular displacement of the flowmeter transmission shaft.

Main faults of flow meter:

1. No oil output
  • Piston stuck
  • Drive shaft stuck
  • Connecting rod stuck
2. Oil leakage
  • Oil seal broken
  • Bolt damaged or loosened
  • The sealing pad seal ring damaged
3. Abnormal noise
  • Bakelite wheel wear
  • Piston wear
  • There is debris inside
4. Oil output is not counted
  • The drive elbow is broken
  • Cross connection block broken

Solenoid Valve video

Solenoid valve:

a device to improve the accuracy of quantitative refueling. In quantitative refueling, due to the existence of “overshoot”, the actual refueling amount is greater than the refueling amount displayed on the display. Installing a solenoid valve can eliminate the overshoot and improve the accuracy of quantitative refueling.

AC contactor:

AC220V voltage controls the on and off of AC380V, effectively preventing the motor from burning out due to phase loss.

Emergency shut-off valve: a reliable oil circuit protection device for submersible pump refueling machines. In case of emergency, such as when the tanker is knocked down or encounters an accidental fire (ambient temperature reaches 200°C±20°C), the valve core will automatically close and cut off the oil circuit.

Switch:

A device that controls the start and shutdown of the tanker

The self-sealing series nozzles of the self-sealing oil gun are suitable for filling operations of light oils such as kerosene, gasoline, and diesel. The self-sealing device integrated into the gun body design can automatically close the oil gun when the container is full to prevent the medium from overflowing. It is convenient for refueling operations and ensures a safe oil supply.

The air inlet nozzle on the self-sealing nozzle is connected to the self-sealing device. This air inlet pipe is actually the “switch” of the oil gun. When the refueling oil floods the air inlet nozzle, the self-sealing mechanism generates a pressure difference to close.

The nozzle has only a separate oil delivery pipe, and the auxiliary valve structure also determines that the oil gun can only discharge oil in one direction, and cannot suck oil or oil gas. Once the oil (or the foam of the oil) floods the air inlet pipe, the self-sealing device will close and the oil gun will stop supplying oil.

Common faults of nozzles include

1. Low flow rate
  • Blockage by debris, the main valve cannot be opened effectively;
  • Wear of parts; C. Loose push rod
2. No oil flow
  • Main and auxiliary valves are broken;
  • The switch handle is broken;
  • Blockage by debris
3. No self-sealing
  • The self-sealing mechanism is broken;
  • Leakage of the adapter sleeve
4. Frequent self-sealing
  • The self-sealing mechanism is broken
  • The inlet pipe is blocked
5. Oil leakage
  • Wear or rupture of the gun body;
  • Bad seal of the adapter sleeve
6. Fuel nozzle cannot be closed
  • There is debris between the main valve and the valve seat, so the valve cannot be closed;
  • Push rod and valve do not match well, and there is a gap;
  • The push rod is not flexible in moving up and down, and the push rod cannot return to its original position after closing the nozzle.

fuel dispenser nozzles

Safety precautions for inspection, maintenance, and maintenance of fueling machine:

1. Refueling operation is prohibited during inspection and maintenance, and operators must wear a full set of anti-static work clothes.

2. Maintenance operation is prohibited before the power supply is cut off for the equipment.

3. Electrical system maintenance operations must be performed by a dedicated person.

4. Explosion-proof tools must be used during maintenance.

5. Control the concentration of combustible mixed gases on site. (If there is oil and gas on the ground, the fuel dispenser can only be operated again after the oil and gas on the ground evaporate and are naturally ventilated.)

6. When cleaning the fuel dispenser, it must be wiped with a pure cotton rag and cannot be rinsed with water. It is forbidden to wipe with gasoline.

Update cookies preferences