Detection method for oil flow in fuel dispenser pipelines

Our company has been designing and producing fuel dispensers for over 20 years. What are the methods for detecting oil flow in fuel dispenser pipelines? In the mid to low-end fuel dispenser market, the measurement of fuel volume mainly relies on converting the rotational signal of the mechanical flowmeter into electrical pulses.

The most widely used among them is the grating orthogonal pulse sensor.

By using a transmissive photoelectric sensor, the rotation signal of the grating connected to the rotating shaft is converted into AB two electrical pulses. This type of sensor has a simple structure and a mature supply chain, so it is being used both domestically and internationally. However, due to this reason, one of its flaws has been magnified. If this mechanical flowmeter or sensor malfunctions, it may cause oil flow in the pipeline, but if the shaft does not rotate, or if the shaft rotates but there is no pulse output, the fuel dispenser motherboard cannot distinguish whether it is not refueling or malfunctioning. In the past, methods such as shutting down after a certain period of time without pulse data were used to avoid this, but there has never been a good solution to this problem.

Here we discuss several methods:

  • Connect a Hall-type turbine flowmeter in series on the pipeline; This flowmeter has a turbine with magnetic poles inside. Under the drive of oil flow, the turbine rotates. Calculate the flow rate through the Hall sensors outside the pipeline. Although it is theoretically determined that the accuracy of this sensor cannot be too high, it can be used as a verification method to detect whether the main sensor is faulty.

Hall effect sensor calculates flow rate

  • Connect a one-way baffle-type oil flow switch in series on the pipeline. The principle of this switch is to use the impact generated by the flow of oil in the pipeline to deflect the baffle, then the baffle drives the micro switch to output a switch signal to indicate the oil flow status. This type of sensor cannot detect flow rate, but as a complementary means of mainstream measurement, it is more than sufficient.

One-way baffle oil flow switch

Both of the above sensors are based on detecting the flow of fuel inside the pipeline. The following situations may occur if fuel flow is detected. Still, there is no pulse output from the main sensor, or if fuel flow is not detected. Still, there is a pulse output from the main sensor, indicating a malfunction. In this case, it is necessary to immediately shut down the motor and solenoid valve and report the sensor failure.