What are the fault characteristics of fuel dispenser display jumps?
1. When there are too many obstacles around the fuel dispenser and the temperature rises due to poor ventilation, the fuel dispenser will often display jumps;
2. Some fuel dispensers will display a small number of numbers before refueling;
3. Some fuel dispensers will display a small number of numbers when the fuel dispenser is self-sealed or closed during refueling;
4. Some fuel dispensers will display a small number of numbers when the fixed-quantity and fixed-quota refueling is completed.

What is the situation when the fuel dispenser display jumps when working?
1. When the temperature of the gas station is high, the gas station often jumps the number of fault phenomenon
If the ventilation is not smooth, the gas station, pipeline, and oil tank will have a temperature rise phenomenon, especially when the gas station canopy is small and the sun shines on the gas station, the pipeline is laid too shallow (the ground is required to be below 500mm), and the pipeline is laid irregularly (the pipeline is required to have a slope of no less than 0.002 from the oil tank to the gas station, and the “几” shape is strictly prohibited), which will cause the oil in the gas station and pipeline to have a high temperature and gasification phenomenon, causing air blockage in the gas station and pipeline, and the number will jump when refueling.
2. Some gas stations jump a small number of numbers as soon as the gun is raised before refueling
Faults caused by damage or aging of the hose:
In the damaged or aged parts of the hose, expansion bulges may appear, and the oil entering the expanded volume space will cause the gas station to jump numbers. After refueling, be sure to retract the hose to the position where the gas station puts the hose to prevent the hose from being crushed by the vehicle and causing damage to the hose. The hose is a consumable part. When the hose is found to be damaged or aged, the gas station should replace it in time.
The aging of the sealing gasket of the return air pipe of the oil and gas recovery coaxial hose causes the fault:
There is also a return air pipe inside the oil and gas recovery. At both ends of the return air pipe, it is isolated from the hose oil circuit by the sealing gasket. Once the sealing gasket is aged and damaged, the oil and gas circuit in the hose will be connected. When the gun is refueled, a small part of the oil leaks into the return air pipe through the damaged sealing gasket, causing the fuel dispenser to jump numbers when the gun is not refueled.
Fault caused by oil gun leakage:
After refueling, there is still a lot of oil in the hose. If the oil gun leaks, when the fuel dispenser is not refueling, the oil in the hose will leak out through the leaking part of the oil gun. The hose needs to be filled up next time, so the jumping numbers appear.
Faults caused by poor sealing of the one-way valve or check valve of the oil pump:
Whether it is a self-priming pump or a submersible oil pump, there is a one-way valve (or check valve). Once the valve is not sealed tightly, part of the oil in the oil pipeline inside the tanker will flow back into the oil tank, causing a large amount of air to enter the pipeline. At the moment of lifting the gun to refuel, the oil or air will reach the oil gun hose through the flow meter, resulting in a jump in the number.

3. Some tankers jump a small number of numbers when the oil gun is self-sealed or closed during the refueling process
Faults caused by excessively long or aging hoses:
When the oil gun is self-sealed or closed during the refueling process, the hose pressure will increase because the oil pump is still working. If the hose is too long or aged, especially the sealing gaskets at both ends of the oil and gas recovery hose return air pipe are aged to cause oil return, the tanker will jump numbers.
Oil gun leakage causes failure:
During the refueling process, when the oil gun is self-sealed or closed, a small amount of oil leaks out through the leaking part of the oil gun. Although the oil gun is in the self-sealing or closed state, it is not closed tightly, so the number jumps.
Failure caused by excessive pressure in the gas station or excessive vibration of the machine:
During the refueling process, when the oil gun is self-sealed or closed, due to excessive pressure in the gas station or excessive vibration of the machine, a part of the oil is pressed into the hose under high pressure. At the same time, the flow meter under high pressure or excessive vibration of the machine causes the internal piston of the flow meter to shake, causing the transmission shaft to swing, and the number to jump. It is recommended to appropriately reduce the pressure of the gas station. When the machine vibrates too much, the damaged components inside the oil pump should be repaired.