Gas filling station safety precautions

1. Safety measures

(1)The sign “Top Ten Prohibitions on Safety Management of Gas Stations” should be set in the gas filling station. The contents of the prohibition are:

  • Smoking in the station is strictly prohibited.
  •  It is strictly forbidden to carry out spark-prone operations such as vehicle maintenance in the station.
  • It is strictly forbidden for motor vehicles to refuel in the station without turning off the engine.
  •  It is strictly forbidden to put on, take off, or slap clothing that can generate static electricity in the station.
  • It is strictly forbidden to use mobile phones, pagers, and non-explosion-proof electrical appliances in the station.
  •  It is strictly forbidden to discharge flammable and explosive materials and dangerous chemicals on the spot in the station.
  •  It is strictly forbidden to use gasoline and volatile solvents to scrub equipment, clothes, tools, and floors in the station.
  •  Pedestrians and bicycles are strictly forbidden to walk through the station.
  •  It is strictly forbidden to operate the gas dispenser by non-operators in this position.
  • Drivers are strictly prohibited from staying away from refueling vehicles.

(2) Obvious safety warnings and warnings should be set in the gas filling station.

(3) Gas filling stations should draw signs in obvious colors to guide gas and filling vehicles to enter and exit the station and stop platforms.

(4) In case of high-intensity lightning and thunderstorms, gas unloading and gas filling operations should be stopped.

gas filling station

2. Electrical appliance management

(1)Electricity consumption management
  •  Electrical equipment and lines should be intact, and electrical connections should be tight and firm, free of corrosion, and meet explosion-proof requirements.
  •  The electrical seal inside the gas dispenser should be checked once a month, and if the seal is found to be poor, it should be repaired or replaced immediately.
  •  The safe electricity consumption of gas filling stations should comply with relevant regulations and temporary electrical lines should not be installed at will in the explosion-proof area of gas filling stations.
  •  It is forbidden to use electric stoves, electric heaters, and other electrical appliances that are easy to cause a fire in business rooms, restrooms, and other places of gas filling stations.
(2)Lightning protection and anti-static regulations
  • The resistance of the connecting wires, jumpers, and grounding devices of lightning protection and anti-static grounding devices shall be tested at least once a year before the thunderstorm season and recorded.
  • Regularly check the electrostatic connecting wires of the gas dispenser, high-pressure rubber hose, and gas unloading site to keep them intact and effective.

gas storage cylinder

3. Equipment management

(1)Compressor
  • The compressor should be fixed firmly and reliably to avoid its vibration affecting other equipment.
  • During a regular inspection, check whether there are any abnormalities in the sound, vibration, and temperature rise of the pump.
  • Check the compressor lubrication system frequently and fill it with lubricating oil regularly. Test the compressor oil once every six months and replace it immediately if it does not meet the requirements. Under special circumstances, laboratory inspections should be arranged at any time, and whether to replace or not should be decided promptly based on the inspection results.
  • Carry out the valve assembly inspection network of the compressor at least once every six months.
  • Regularly check the connection parts of each component of the pipeline to keep it well-sealed and free from leakage.
(2)Gas dispenser
  • The sealing surfaces of the gas dispenser should be checked regularly to ensure that there is no leakage.
  • The gas dispenser must have safety devices such as emergency cut-off, over-current cut-off, pull-off cut-off, safe backflow, etc., and keep them intact and effective. The inflation nozzle of inflation nozzle should have a self-sealing function.
  • The safety device of the gas dispenser should be regularly tested to ensure the safe operation of the gas dispenser.
(3)Valves and safety accessories
  • The valve should be maintained regularly to keep the opening and closing flexible without leakage.
  •  The emergency shut-off valve should be calibrated once a month, and the valve should be closed within 3 seconds after pressure relief to ensure It functions in an emergency.
  • Safety accessories on gas storage tanks or gas storage wells, pipelines, and gas dispensers should be regularly verified and calibrated according to relevant national regulations: high-pressure gas storage cylinders once every three years; Pressure gauge and thermometer once every six months; Flowmeter once every six months; The liquid level gauge should be calibrated once every time the tank is opened for inspection; The safety valve should be calibrated at least once a year.
(4)Equipment maintenance
  • Gas filling stations should be equipped with equipment management personnel, and the equipment maintenance management system should be conscientiously implemented.
  • Gas filling stations should prepare equipment maintenance plans, keep operation and maintenance records, and establish complete technical files of equipment and pipelines.

Special vehicle for transporting gas cylinders

4. Gasing operation

(1) It is strictly forbidden to fill up automobile gas cylinders without the inspection certificate of the technical supervision department. It is strictly forbidden to fill any gas device or gas cylinder other than an automobile gas storage cylinder;

(2) During operation, each air dispenser should have one operator, but one person should not operate two air dispenser nozzles at the same time; 3. The operator should stand on the side to guide the vehicle into the station, and the vehicle should stop at the designated position with obvious signs and keep a distance of more than 1m from the gas dispenser;

(3) After the vehicle has stopped, the operator should supervise the driver to tighten the handbrake, turn off the engine, remove the key from the

Vehicle and leave the cab. The lights should be semi-turned off at night;

(4) Before filling the gas, the operator should conduct a safety inspection on the gas cylinder instruments, valves, and pipelines of the vehicle to check whether they are in service life;

(5) The aerated glue (soft) pipe should not cross or bypass other equipment during operation;

(6) When compressed natural gas is emptied, it is strictly forbidden to aim the muzzle at people;

(7) During the gas filling process, attention should be paid to monitoring whether the pressure of the metering instrument of the gas filler is normal. The pressure of compressed natural gas should not exceed 20MPa;

(8) During the gas filling period, operators should not leave the site, and it is strictly forbidden for non-operators to operate on their behalf, and it is strictly forbidden for non-operators to take the initiative to fill;

(9) In case of emergency (such as vehicle or equipment leakage) during the gas filling process, the operation should be stopped immediately;

(10) After filling, close the filling nozzle, the gas storage cylinder valve, and the filling pipe valve, remove the filling nozzle, close the protective cover of the filling port, approve the filling quantity, and confirm that there is no air leakage before starting the vehicle;

(11) During the gas receiving, unloading, and gas filling operations, the safety officer should regularly inspect the operating parameters of the gas storage tank, and stop the gas filling operations in case of abnormality.

Update cookies preferences
WhatsApp

Get a Quick Quote!

x

    Get a Quick Quote!

    x