Hidden dangers of oil leakage in CNG reciprocating compressors

Reciprocating compressors have extremely wide applications in the natural gas field. Their main principle is to make the mechanical energy of the motor convert into the internal energy of the working medium, thereby achieving the transportation of the medium and other process flows.

CNG reciprocating compressors

Compressors often operate well during the initial stage of use, but after long-term operation, some units will experience obvious oil leakage. The leakage of lubricating oil not only causes pollution to the environment but also leads to certain economic losses. Therefore, solving the problem of oil leakage is of vital importance for the maintenance and upkeep of compressor units.

1. Lubricating Oil Leakage: The Evolution from “Minor Seepage” to “Major Accident”

As the core equipment in the CNG compression process, the sealing performance of the hydraulic and lubrication systems of the hydraulic reciprocating compressor is directly related to operational safety. In the early stage of Lubricating Oil leakage, it may be manifested as oil seepage from the joint and oil dripping from the seal. However, under high pressure (usually 15-25 MPa) and high-frequency reciprocating conditions, the leakage will deteriorate rapidly.

2. Multi-dimensional Hazards:

(1) Safety red line: Risk of detonation and explosion.
  • Oil-gas mixed explosion: The leaked hydraulic oil forms a dangerous mixture with CNG. It may catch fire upon contact with high-temperature components (such as cylinder walls, exhaust pipes) or static sparks. An explosion may occur when the concentration meets the standard.
  • Chain reaction of system failure: The loss of hydraulic oil causes a sudden pressure drop, and abnormal operation of the piston triggers mechanical shock, which may cause equipment rupture and natural gas leakage.
(2)Equipment failure: Core components are scrapped at an accelerated pace.
  • Hard damage caused by lubrication failure: Components such as pistons and crankshafts have been subject to long-term “dry friction”. In the short term, issues such as cylinder scoring and bearing seizure may occur, and in severe cases, crankshaft breakage or cylinder block cracking can happen, leading directly to equipment shutdown with repair periods lasting several weeks.
  • A sharp decline in hydraulic efficiency: The output pressure of the hydraulic pump is insufficient, and the compression capacity drops by 30% to 50%, causing the CNG storage tank to fail to reach the rated pressure (usually 20MPa), which affects the normal supply of gas to the gas filling station or industrial use.

CNG container substation structure

3. Emergency Response: 3 Steps to Prevent Risk Spread

(1)Stop the machine immediately and cut off the power supply

Upon discovering Lubricating Oil leakage, immediately press the emergency stop button, close the intake valve of the compressor, and the power supply. Shut off the natural gas and power source to prevent continued mixing of oil and gas.

(2)On-site control to prevent secondary disasters

Open flames and switch electrical equipment are strictly prohibited. Turn on the ventilation system to reduce the concentration of oil mist. Cover the leak point with oil-absorbing cotton and collect the leaked oil (direct dumping is strictly prohibited).

(3)Precise investigation and repair

Focus on inspecting the aging condition of sealing parts (such as piston rod seals and flange gaskets), the tightness of hydraulic pipeline joints, and whether there are cracks in the cylinder body/pump body. After replacing the damaged parts, a pressure test must be conducted (maintaining pressure for 30 minutes without pressure drop) before restarting.

L-CNG Skid

4. Three steps to establish long-term prevention and control:

  • Periodic inspection: Confirm the oil level gauge and sealing parts daily, test the pressure curve of the hydraulic system weekly, and take samples to analyze the oil quality (moisture and impurity content) monthly.
  •  Spare parts upgrade: High-pressure resistant and anti-aging fluororubber seals are adopted to replace traditional nitrile rubber, thereby extending the service life of the seals.
  • Personnel training: Regularly conduct oil leakage fire drills to confirm that operators can complete the shutdown and initial handling within three minutes
  • Special reminder: As the core equipment of the CNG station, the selection of CNG compressors should be of high quality. Choosing BlueSky’s CNG station and compressors offers high-quality products and provides complete training and after-sales service.