EFMC is a portable industrial flow meter with a more flexible installation method and a high-precision microcomputer. It is suitable for a variety of different application scenarios. It is equipped with an electronic meter head and a printer. It is highly accurate and stable and can print each refueling data and query previous transaction records.

EFMC volume preset refueling operation:
(1) Display interface

(2) Volume preset refueling operation.
The maximum volume preset value is 9999.99. However, any refueling can be greater than 9999.99. For example, if 9999.99 is added, 10000.0 will be displayed, and the decimal point will automatically move back one place.

1) In standby mode, press the [MODE] key to switch to VOLUME mode. If you cannot switch to VOLUME mode, press the [FINISH] key first.
2) Press [PRESET] to enter the preset interface. There are four options:
- [PRESET LITERS] Input any preset value
- [LITER PRESET1] Common preset value 1
- [LITER PRESET2] Common preset value 2
- [LITER PRESET3] Common preset value 3
3) Press [+] or [-] to select [PRESET LITERS], and press [NEXT] to enter the modification interface.
4) Press [NEXT] to select the number of digits to be modified, press [+] or [-] to change the size of the digits, and press [ENTER] to confirm and exit the modification interface after the coefficient modification is completed.
5) Press [MODE] to exit SETUP mode.

- 1 M-80-1 flow meter displacement: 1.839 liters/rev
EFMC is calculated based on a single pulse, and the 100 pulse sensor is calculated based on 50 coefficients, EFMC coefficient 1.839/50 = 0.03678. If the unit is gallons, the coefficient is 0.01400/3.785 = 0.03699. The 200 pulse sensor is calculated based on 100 coefficients, EFMC coefficient 1.839/100 = 0.01839.
- 2 M-50-1 flow meter displacement: 0.681 liters/rev (actually 0.7 liters/rev)
EFMC is calculated based on a single pulse, and the 100 pulse sensor is calculated based on 50 coefficients, EFMC coefficient 0.7/50 = 0.01400. If the unit is gallons, the coefficient is 0.01400/3.785=0.03699. The 200 pulse sensor calculates the coefficient as 100, and the EFMC coefficient is 0.7/100=0.007000.