How to detect solenoid valve malfunctions?

How to diagnose a malfunctioning solenoid valve? Let’s explore the causes of solenoid valve malfunctions:

1. No oil comes out, or the flow rate is low

Generally speaking, first check whether any foreign matter is stuck in the solenoid valve’s mechanical parts, then check the solenoid valve for malfunction. You can check this way: Touch the outside of the solenoid valve with your hand when turning on the machine to see if there is a feeling of impact, and then listen for a “pop” sound. If there is, it is not the solenoid valve’s fault. If not, check whether the 220V power supply that provides the solenoid valve is normal. Use a multimeter to verify that the voltages at the large and small valve terminals and the common line are 220V when starting up. If so, it is most likely caused by the solenoid valve coil being burned out, which can be replaced.
Most problems with low flow rates are caused by the solenoid valve failing to open. You should check whether the solid-state relay controlling the large valve is burned out. The check method is to use a multimeter to measure the voltage between the terminal of the large valve and the public line on which the machine is running. It is about 220V. The coil is burned out. If not, the solid-state relay controlling the large valve on the power supply board is broken. If the oil does not come out when it is close to the preset value, it is mostly because the small solenoid valve cannot open. The inspection method is the same as above.

solenoid valveS

2. No low flow rate during preset refueling

First, check the setting of the tanker’s early shutdown valve. If it is “0.00”, just reset it. Secondly, check for any wiring errors during maintenance of the large and small valves. If the problem is not solved after the correct check, you should consider the control function on the power supply board. The valve relay is damaged.

3. The coil is burned out

After powering on, the solenoid valve does not produce oil, the coil appears abnormal, and the core rod built into the coil has no electromagnetic suction. The solution is to replace the solenoid coil.

4. Internal leakage

When the solenoid valve cannot be closed after cutting off the power supply, it was observed on-site that,  after the preset quantity is reached, the oil gun remains open and the flow rate persists. The reason may be that the diaphragm is damaged or that foreign matter in the valve parts prevents the main valve from closing. The solution is to replace the diaphragm or clean the valve parts
In actual work, measurement inspectors and maintenance personnel often encounter problems with inaccurate fuel metering and solenoid control valve failures. Only through proper understanding, use, and maintenance of solenoid valves can accurate measurement results and consistent value transmission be maintained. Only in this way can the fault be correctly diagnosed and resolved in time to ensure the solenoid valve operates normally.