Why do we need to purify natural gas at CNG stations?
The purpose of natural gas purification at CNG stations is to remove impurities such as acidic gases and water that do not meet CNG quality standards, and to remove nitrogen and oxygen when necessary, so it can also be called deep impurity removal or purification. The purification treatment in the CNG station is also to meet the technical conditions of the operation of various process equipment in the station and achieve the purpose of maintaining a good operating state.
Natural gas deacidification at CNG stations
Removing acidic gases is referred to as deacidification. Deacidification is used to control the corrosion of acidic gases and acid solutions formed by acidic gases and water on metal pipes and equipment. The acidic gases that need to be removed from CNG stations are mainly hydrogen sulfide and carbon dioxide. Removing hydrogen sulfide is referred to as desulfurization, and removing carbon dioxide is referred to as decarbonization. The high-strength steel used in high-pressure equipment and pipelines in CNG stations is particularly sensitive to hydrogen sulfide. When the hydrogen sulfide content is high, “hydrogen embrittlement” is prone to occur, causing steel failure. According to the quality requirements of compressed natural gas for vehicles, the hydrogen sulfide content must be controlled below 15mg/m3. When the hydrogen sulfide content in the incoming natural gas is less than the content specified by the CNG quality requirements, desulfurization treatment is not required. However, when the high-strength steel used in gas storage facilities and compressors has more stringent hydrogen sulfide content requirements, further precision desulfurization should be performed.

Natural gas decarbonization at CNG stations
GB17820 stipulates that the carbon dioxide content of natural gas of Class I and II quality is not more than 3% (volume percentage), and no further removal of carbon dioxide is required. However, if the quality requirements are not met, carbon dioxide should be removed. The critical pressure of carbon dioxide is 7.4MPa, and the critical temperature is 31°C. CNG stations can use pressurized condensation to remove carbon dioxide instead of other decarbonization processes.
Natural gas dehydration at CNG stations
Dehydration is mainly to prevent water and acidic gas from forming acidic solutions and then corroding metals, and to prevent compressed natural gas from freezing during decompression and expansion and causing ice blockage. Usually, the water dew point of natural gas entering the station (such as the water dew point of natural gas of the quality specified in GB17820 is only required to be 5°C lower than the ambient temperature at the pressure and temperature of the junction point) is much higher than the water dew point under the use conditions required by CNG quality (such as 20MPa or even 25MPa, at least below -13°C), and the absolute water content is dozens of times higher. Therefore, CNG stations must carry out deep dehydration.
Natural gas dehydrogenation at CNG stations
The quality index of compressed natural gas for vehicles (GB18047) requires that there should be no liquid hydrocarbons in compressed natural gas at the operating pressure and temperature. Under high pressure, gaseous heavy hydrocarbons will liquefy, so CNG stations need to be dehydrogenated. Dehydrogenation at CNG stations refers to the removal of hydrocarbons of C3 and above in natural gas to prevent abnormal ignition of NGV engines. In addition, dehydrogenation can also prevent some heavy hydrocarbons from being adsorbed by molecular sieve adsorbents and the like, which will affect the removal of other impurities by molecular sieves. Generally, CNG stations do not need to have dedicated dehydrogenation facilities. When the content of heavy hydrocarbons in natural gas is relatively high, the dehydrogenation effect is very good after compressor pressurization and condensation separation.
Natural gas deamination in CNG stations
Deamination is mainly to reduce the amount of NOx produced during the combustion of natural gas. Deoxygenation is to prevent it from accelerating oxidation reactions on equipment materials under high pressure. When the natural gas entering the CNG station meets the quality standards of urban gas, denitrification and deoxygenation are not required according to the current domestic standards.
Configuration of the purification process
The location of the above-mentioned purification process should be determined after comprehensive analysis based on the technical conditions of CNG station construction, the quality of the natural gas entering the station, the process conditions and operating technical parameters of the purification equipment, the quality requirements of compressed natural gas, and the technical and economic feasibility of equipment selection. In the purification process flow of CNG stations, purification treatments are generally arranged before, during, and after natural gas compression, which are respectively called pre-compression treatment (referred to as pre-treatment or pre-treatment), compression treatment, and post-compression treatment (referred to as post-treatment or final treatment).
Desulfurization device
When the CNG station adopts the normal temperature dry desulfurization process, the desulfurization device is usually configured as the first purification process. The advantage of this configuration is that it can avoid the corrosion of hydrogen sulfide to subsequent process equipment and pipelines to the greatest extent, and the manufacturing of the desulfurization equipment running in the low-pressure section of the station is simpler than that of the high-pressure section, and the operation and replacement of the desulfurizer are relatively easy. If a dry desulfurization process that moisturizes the desulfurizer is used, it must be set in the first process so that the subsequent process can deeply dehydrate its exported natural gas. When the molecular sieve adsorption desulfurization process is used, the process equipment for simultaneous dehydration and desulfurization should be used, which is generally also configured before the compressor. If the compressor has no special requirements for acidic gas, especially hydrogen sulfide and water content, it is also possible to consider configuring a high-pressure molecular sieve dehydration and desulfurization device after the compressor.

Dehydration device
In general, a CNG station only needs to set up a set of dehydration devices, which can be configured before, during, or after compression. The following situations should be set up before compression: the water content of the incoming natural gas is higher than the limit requirement of the compressor; wet desulfurization or humidified dry desulfurization process is used; the natural gas after compression carries out more oil and it is not suitable to set up a dehydration device after the compressor; the ambient temperature of the gas storage facility is lower than 0°C (but the working temperature of the dehydration device should not be lower than 0°C), etc. The following situations should be set up after compression: the heavy hydrocarbon content in the incoming natural gas affects the dehydration effect of the dehydration device; the inlet pressure significantly affects the compressor inlet pressure requirement due to the pressure loss of the dehydration device and its pipeline system. The dehydration device, after compression, should have a damping device to reduce the pressure fluctuation in the device (such as when the fast charging system is used) to ensure its dehydration time and reduce the mechanical effect on the desiccant. When it is not appropriate to configure the dehydration device before and after the compressor, a compressor that allows intermediate dehydration and has an interface should be selected, and an intermediate dehydration device should be configured. Other situations can be flexibly configured before, during, or after compression.