How to Select Compressors for a CNG Station?

The compressor is the most important piece of equipment in a CNG station. The CNG station should comprehensively analyze and compare factors such as design scale, gas source conditions, supply load characteristics, production system, gas storage and regulation capacity, and expansion plans to determine the model and quantity of compressors.

CNG compressor

Compressor Selection Principles

  • CNG station natural gas compression is characterized by high pressure and medium to low flow rates; therefore, the compressor type should preferably be a rotary compressor.
  • For ease of production, operation, and maintenance, compressors from the same series should be selected. The discharge pressure should be the same and should not exceed 25 MPa.
  • The compressor displacement should meet the production needs. To adapt to economical operation under different production loads, compressors with different single-unit capacities can be selected, but no more than two types should be chosen.
  • The total number of compressors in a CNG station should not exceed 3, with only 1 compressor recommended for substations. One compressor should be provided as a backup for the main refueling station.
  • The prime mover should be an energy-efficient model. An electric motor is preferred, but a natural gas engine can also be used.
  • CNG stations within urban areas should select compressors with good dynamic balance, low vibration, and low noise.
  • When both performance and energy consumption are optimal, oil-free (cylinder) lubrication compressors are preferable.

CNG station

Compressor Selection

Types of Compressors

Mainly include reciprocating, centrifugal, axial, and rotary compressors. Based on the process conditions of CNG stations, the compressors are high-pressure (discharge pressure 10~100MPa), medium, and small (volume flow rate not exceeding 60m3/min under inlet conditions is medium-sized, not exceeding 10m3/min is small) compressors. Most use oil lubrication or cylinder oil-free lubrication.

Reciprocating Piston Compressors (hereinafter referred to as Reciprocating)

Suitable for situations with small displacement and high pressure ratio, it is the preferred compressor type for CNG stations. The pressure ratio of reciprocating compressors is usually 3:1 or 4:1, and a multi-stage configuration is possible, with each stage pressure ratio generally not exceeding 7. Small compressors can reach a maximum outlet pressure of 40MPa. The flow range is 0.3~85m3/min. When the natural gas source for a CNG station comes from a medium-pressure urban pipeline network, the compressor inlet pressure is generally 0.2~0.4MPa. Even at a minimum of 0.035MPa, a reciprocating compressor can be used. When connected to a high-pressure pipeline network or main gas transmission line, pressures can reach 4.0MPa, or even as high as 9MPa. Except for compressors specifically designed for CNG storage with outlet pressures determined through comparative analysis, the outlet pressure of CNG station compressors is typically 25MPa. The displacement of a single compressor at a CNG station is generally 250~1500 m3/h.

CNG refueling stations

Structurally

CNG compressors can be classified as vertical (Z-type), horizontal (D-type, M-type, H-type), and angled (V-type, W-type, L-type, T-type, fan-type, and star-type, etc.). Vertical compressors have a small footprint and can be oil-free lubricated, but they experience greater vibration. Horizontal (also known as symmetrical balanced) and angled compressors have a compact structure and stable operation. Horizontal compressors offer the best dynamic balance and are widely used in CNG stations.

CNG station compressors are typically installed in the form of compressor units

A compressor unit includes a compressor main unit, prime mover, lubrication system, cooling system, operation and control system, and auxiliary systems such as safety venting and oil (water) gas separation. The compressor main unit primarily consists of the compressor body, cylinders, pistons, transmission mechanism, and intercooler, as well as auxiliary components such as safety pressure relief and venting. CNG stations typically use 3 to 4 stages of compression, corresponding to 3 to 4 cylinders. The cylinders are arranged in series, with adjacent stages (cylinders) compressing the medium to the rated pressure at the same or nearly the same compression ratio. Intercoolers are installed between cylinders to improve compression efficiency. The intercoolers can separate some of the oil, hydrocarbons, water, and cylinder lubricating oil that precipitates out due to the condensation of the medium (such as natural gas), and can organize the discharge to the oil collection tank.

CNG Compressor Circulating Water Cooling System

Small compressors in CNG refueling stations are configured with air cooling. Cooling water enters the compressor’s intercooler and cylinder liner cooling unit, then flows back to the cooling tower.

Compressor Heat Exchanger

Compressor Operation and Control System

This includes a local control panel (box) and an external automatic control system. Operation and control functions include start-up condition detection (start-up parameters for oil, water, and gas lines), start-up, operating status monitoringand manual shutdown. It can also be configured for intelligent operation control, such as automatic start-up and shutdown based on refueling needs.

Some CNG stations also use integrated compressor units

Large integrated compressor units have a high degree of automation. Each unit (skid) is equipped with a charging priority control panel and a skid-mounted PLC. This, along with the motor control center, gas storage system, air-cooling system, pneumatic valves, and instrument compressed air system, forms a complete compression system. The functions of all equipment in this system, including compressor unit start-up priority control, operation sequence function, start-up mode selection function, cooling and shutdown function, charging priority control function, operator emergency shut-off (ESD) function, and air compressor start/stop function, are all centralized on the PLC panel in the main control room. The main PLC can determine when to start and which unit (compressor unit) to start. The skid-mounted PLCs only monitor the compressor functions, issue alarms when abnormal operation occurs, and control the operation of all valves. The complexity of the PLC control functions directly affects the investment in the plant.