A self-priming pump is a centrifugal pump capable of delivering a certain pumping capacity under suction conditions. It primarily combines gas-liquid mixing with a specialized pump structure to draw in gas. A certain degree of vacuum can be achieved within the pump’s suction line, thereby enabling centrifugal action.

The self-priming pump is not turning and is not producing oil
Clogged Fuel Dispenser Filter
A clogged fuel dispenser filter will cause the pump to be louder than usual, dispense fuel slowly or not at all, and make a deep, muffled sound.
Motor Reversing
Swap two of the live wires on the fuel dispenser’s power switch.
Loose Belt
Fuel dispensers that have been used for a long time may have a loose belt. Adjusting the motor will solve the problem, but the belt should not be overtightened. The fuel dispenser belt should be checked regularly.
Bottom Valve Not Opening
Foreign objects are stuck in the bottom valve, preventing it from opening, which will also prevent the self-priming pump from dispensing fuel.
Check Valve Not Opening or Malfunctioning
A check valve can be used when a single pipeline supplies fuel to two or more self-priming pumps.
A check valve is not needed when a single pipeline supplies fuel to a single fuel dispenser.
Damaged Fuel Nozzle
The fuel nozzle cannot be opened or is clogged, preventing fuel from being dispensed.
Air Leak in the Pipeline
This occurs when replacing the bottom valve or at the pipe flange connection.
Deformed Pipeline
Deformed pipelines are more common in gasoline. They only cause the pump to fail to draw fuel in hot weather. (This mainly occurs in older gas stations where the construction team was unprofessional, the pipeline trench was poorly constructed, and the pipeline subsided in a certain section.) The solution is to install a submersible pump and re-lay the pipeline.
Self-priming Pump Usage Precautions
- Running the pump without liquid is strictly prohibited. Unless a self-priming pump designed for dry running is used, it must not be run dry.
- Before using the self-priming pump, open the inlet and outlet valves. After connecting the power supply, briefly press the start button to check if the motor reverses direction.
- When using the self-priming pump, the outlet valve must not be completely closed. If it is necessary to stop liquid delivery, close the inlet valve, but the duration should not exceed 2 minutes. If this time exceeds 2 minutes, stop the pump immediately to prevent damage.
- After the self-priming pump is stopped, the inlet and outlet valves can be completely closed.
Aging or damage to the solenoid valve, meter, pump body check valve, pump body overflow valve, and various connecting gaskets can also prevent a self-priming pump from drawing fuel.