Hydraulically Driven Skid-Mounted Integrated Hydrogenation Unit

The skid-mounted integrated hydrogenation unit integrates hydrogen unloading and compression. The hydrogen unloading system includes automatic/manual shut-off valves, nitrogen purging/replacement interfaces, and an inlet pressure display.

Skid-Mounted Hydrogenation Unit

Skid-Mounted Unit Operating Conditions

  • Compressed Medium: High-purity hydrogen conforming to GB/T 37244-2018 “Fuel Hydrogen for Proton Exchange Membrane Fuel Cell Vehicles” standard;
  • Replacement/Purge Nitrogen Pressure: 0.6~0.8MPa.
  • Instrument Air Source Parameters: Instrument air medium is nitrogen or compressed air, pressure range 0.5~0.8MPa, minimum flow rate 0.17m3/min.
  • Voltage: 380V±5%, 50HZ;
  • Foundation Requirements: Skid platform dimensions ≥3600X2300 (mm), platform flatness ≤±5mm, levelness ≤±5°.
  • The unloading section adopts an integrated panel-type hydrogen unloading system, including a main valve and pressure gauge.

Main Features and Advantages of the Unit

  • The compression section adopts a hydraulic drive, with only sealing rings as the most vulnerable parts.
  • The hydraulic compressor requires no unloading and can be started at any time: Because the compressor cylinder is hydraulically driven, the hydraulically driven compressor does not require unloading.
  • The compression cylinder features oil-gas cylinder separation. The cylinder piston uses oil-free lubrication, preventing contamination of the compressed medium during compression. Both the gas chamber seal and oil chamber seal employ multi-stage sealing and a special oil-gas isolation chamber design, eliminating oil-gas contact.
  • The hydraulically driven compressor has a low operating linear speed and low reversing frequency. Compared with other types of reciprocating machines, the hydraulically driven compressor has an extremely low reciprocating frequency and piston linear speed, resulting in a long service life for seals and valves.
  • The compressor cylinder piston is driven by a hydraulic system, resulting in low vibration and low noise. The motor drives a high-pressure oil pump, which then acts on the compression cylinder. The motor load and working conditions are stable, extending the service life of the compression cylinder and the motor.
  • Fully water-cooled structure, high heat exchange efficiency, low exhaust temperature, and low system operating temperature.
  • The unloading end panel integrates the unloading main valve and pressure gauge, which can be directly connected to the tank truck with a hose, or a rigid pipe can be led out and then connected to the tank truck via a hose.
  • The hydrogen refueling end integrates a panel-type hydrogen refueling machine with refueling and shut-off functions.

Unit Safety Design

  • The unit is equipped with minimum inlet pressure protection, filter differential pressure protection, interstage pressure overpressure protection, maximum outlet pressure protection, maximum outlet pressure secondary protection, and each stage outlet temperature protection. (2) Automatic start/stop protection and automatic safety control system protection for the unit;
  • Installation of an outlet safety valve;
  • Installation of a compression ratio alarm function, which alarms and shuts down when the compression ratio exceeds the set value;
  • Installation of a filter differential pressure alarm function to prompt for filter cleaning;
  • Installation of one hydrogen leak alarm probe with a detection range of 0-4%; a hydrogen concentration alarm installed 15 cm above the container, which alarms when hydrogen concentration reaches 0.4% (i.e., 10% of the lower explosive limit); and alarms and shuts down when hydrogen concentration reaches 1% (i.e., 25% of the lower explosive limit), while maintaining the exhaust fan operation until the hydrogen concentration drops to a safe range; a flame detector installed inside the container, which alarms and shuts down when a flame is detected;
  • Functions for judging, self-recovering, alarming, and shutting down abnormal parameters, sudden changes, and logical system abnormalities in the unit;
  • Alarms for pressure, temperature, and liquid level detection in the hydraulic system;
  • Alarm protection for abnormal compression cylinder frequency and stroke;
  • An electrostatic grounding alarm device for unloading and refueling. (11) The hydrogen refueling gun is equipped with a breakaway valve (breakaway force 400~600N), an electrostatic grounding interface, and a human body electrostatic discharge post.
  • The hydrogen refueling operation panel and touch screen are located on the side of the hydrogen refueling gun for easy observation and operation. The emergency shut-off button is located on the same side.
  • The internal gas pipelines of the unit are cooled through multiple stages to ensure that the gas cylinder temperature does not exceed 85°C during the refueling process.
  • The chiller unit is linked to the integrated skid, and alarms and shutdowns are triggered when water pressure or temperature is abnormal.

Filtration of the Unit

The inlet protective filter of the unit has an accuracy of 10μm to ensure that the hydrogen entering the unit is pure and free of impurities. There is no oil or impurity contamination during the operation of the unit, and a 5μm protective filter is required at the outlet.

Design of Unit Unloading, Sewage Discharge and Recycling Process

The structural characteristics of the liquid-driven compressor determine that the unit can be started at any time within the working pressure range. Therefore, this equipment does not have an unloading system or a sewage recovery device. Start-up and shutdown do not require venting, greatly simplifying unit operation, reducing compressor gas consumption, and eliminating malfunctions caused by unloading system failure.

Lubrication System

The compressor uses an oil-free lubrication design, eliminating the need for a lubrication system. The extremely low reciprocating speed and special sealing design result in extremely low frictional heat and ensure a very low wear rate, thus eliminating the need for oil-lubricated cooling of the compressor cylinders. Furthermore, the compressor does not have a crankshaft connecting rod structure, and there are no crankshafts, connecting rods, crossheads, sliders, or other sliding bearings requiring forced lubrication, thus eliminating the need for a corresponding lubrication system.

Equipment Materials and Design

  • The high-pressure cylinder inside the compressor main unit is made of 316L material, treated with a special process to achieve high hardness and strength while effectively preventing hydrogen embrittlement. The piston and piston rod are made of alloy material and undergo special heat treatment to achieve high strength and high wear resistance.
  • The valves are made of stainless steel with a special surface treatment to enhance sealing performance and extend service life.
  • All high-pressure hydrogen pipelines and valves are made of 316L stainless steel. High-pressure stainless steel fittings and pipes operate at a pressure of 20,000 PSI to ensure reliability.
  • Pipeline Material Selection: All high-pressure pipelines are made of 316L stainless steel, conforming to GB50516-2021 requirements, with a Ni content ≥12%, and inner surface polishing and degreasing treatment.
  • Fitting Material Selection: Elbows, tees, reducers, and other fittings in the skid for high-pressure pipelines above 20MPa are connected using threaded (C&T) connections.
  • Low-pressure pipelines of 20MPa and below are connected using compression fittings or welding.
  • Safety Valve Venting and Replacement Process: The venting pipelines of the unit system converge at the unit outlet venting main pipe and exit the skid, with a reserved venting port. A manual venting bypass valve is installed before the safety valve at the high-pressure pipeline outlet for convenient maintenance. Replacement interfaces are provided at the unit inlet and outlet for convenient nitrogen replacement and hydrogen sampling.
  • Cooling System: The entire unit is water-cooled. Water-cooled radiators directly cool each stage outlet of the compressor and the hydraulic oil system. Real-time monitoring of the water cooling circulation temperature and status is provided, with alarms for abnormal circulating water temperature or stagnation.

The hydraulic oil is equipped with an automatic heating system. When the ambient temperature is low, the hydraulic system automatically heats up, and the unit starts normally once the oil temperature reaches the set value.

The chiller is installed separately outside the skid and requires connection to the skid’s inlet and outlet water pipes. Unless otherwise specified, the chiller is not included in the default supply.