Introduction to the principle of urea heating system

Winter is coming, and many masters have encountered this urea heating failure. This article will give a brief introduction to the principles of the urea heating system.

Introduction to automotive urea solution

Urea will freeze in winter. The standard concentration of urea is 32.5%, and the freezing point is minus 11 degrees. Therefore, in cold areas in winter, urea will freeze. So in winter, the urea heating system will work, so it often reports failures.

Automotive urea solution

Automotive urea solution is also called exhaust gas treatment fluid, Add Blue, AdBlue, and DEF solution.

  • Urea content requirement: 31.8%-33.2%.
  • Chemical composition: NH•CO•NH2 (ammonia water) + H2O (deionized water).
  • Colorless and transparent.
  • Freezing point: -11°C (content below 32.5%).
  • Volume expansion rate: 7% (at freezing point).
  • Corrosiveness: alkaline at high temperature (pH 9- 11).
  • It cannot contain metal ions (calcium, iron, copper, zinc, chromium, nickel, magnesium, sodium, potassium, and aluminum).

Introduction to the heating principle of the urea system

The components that need to be heated in the current urea system are the urea tank, urea pump, and urea pipe.

Schematic diagram of urea heating system

  • The urea pump, urea injection pipe, urea inlet pipe, and urea return pipe are electrically heated.
  •  The urea tank is heated by engine cooling water.
  •  The urea nozzle is cooled by a separate engine cooling water branch (not controlled by the cooling water control valve switch; that is, as long as the engine is running, there is cooling water to cool the urea nozzle).

Conditions for starting urea system heating

  • Urea pipeline: When the ambient temperature is lower than -2 degrees, the urea pipeline starts heating, and when the ambient temperature is higher than 0 degrees, the urea pipeline stops heating.
  •  Urea pump: When the temperature of the urea pump is lower than -2 degrees, the urea pump starts heating, and when the temperature of the urea pump is greater than 30 degrees, the urea pump stops heating.
  •  Urea tank: When the temperature of the urea tank is lower than 0 degrees, the urea tank starts heating. When the temperature of the urea tank is greater than 10 degrees, the urea tank stops heating.

Knowledge of the urea system heating relay number:

Many maintenance stations do not know which heater this relay number corresponds to. Now, it is sorted out as follows:

  • Heating relay 2-urea pump heating relay.
  • Heating relay 3-urea injection pipe heating relay.
  • Heating relay 4-urea return pipe heating relay.
  • Heating relay 5-urea inlet pipe heating relay.