Introduction to vane-type combined pumps

Structurally, it adopts a blade-type design, resulting in a high flow rate and a high vacuum. It employs an advanced oil-gas separation system with a large separation volume and thorough oil-gas separation. It features a compact structure, easy operation, and reliability. Let’s take a look at the working principle of the vane-type combined pump!

vane type combined pumps

Working principle of the vane-type combined pump

The motor drives the rotor shaft of the combined pump to rotate. The blades, propelled by their own weight and the centrifugal force of the thrust ring, adhere tightly to the pump chamber. The upper closed volume, surrounded by the rotor, blades, and pump body bushing, continuously decreases, discharging liquid through the oil outlet; the lower closed volume continuously expands, drawing liquid in through the oil inlet. The oil rotates within the fluid passage through a vortex tongue, separating oil and gas. The separated oil is discharged from the outlet, the oil-gas mixture enters the oil-gas separation chamber, and the gas is discharged through the exhaust port.

Structure, Technical Parameters, and Environmental Conditions:

Structure:

The JBL50 high-flow combined pump consists of a pump body, pump cover, rotor assembly, pump body bushing, fluid passage assembly, control valve, float, filter screen, and overflow valve device. All materials selected in the design meet standards. For example, the pump body and pump cover are made of ZL104 stainless steel, the pump body bushing is made of HT200 stainless steel, the float material is made of polyoxymethylene, the blades are made of M356F stainless steel, and the seals are made of nitrile rubber and oil-resistant cork gaskets, etc.

Technical Parameters:
  • Outlet Pressure: ≤0.3MPa;
  • Flow Rate: 50L/min;
  • Dry Vacuum: ≥0.054MPa;
  • Wet Vacuum: ≥0.07MPa;
  • Speed: 680 rpm/min;
  • Motor Power: 0.75KW;
  • Operational Stability: After the combined pump operates continuously for 100 hours at maximum flow, the change in metering accuracy is no greater than 0.15%.
  • Noise: ≤72dB(A)
  • Current: ≤2A
  • Environmental conditions: a) Temperature: -40°C~+55°C;
  • Relative humidity: 30%~80%; c) Atmospheric pressure: 86KPa~106 KPa;

Vane Pump Types

Single-Acting Vane Pump

The working principle of a single-acting vane pump is shown in the figure. It consists of a rotor 1, a stator 2, vanes 3, and end covers. The stator 2 has a cylindrical inner surface, and there is an eccentricity e between the stator 2 and the rotor 1. The vanes 3 are installed in the rotor slots and can slide within them. When the rotor 1 rotates, centrifugal force causes the vanes 3 to press against the inner wall of the stator. This creates several sealed working spaces between the stator 2, rotor 1, vanes 3, and the two side distribution plates. When the rotor 1 rotates counterclockwise, on the right side of the figure, the vanes 3 gradually extend, increasing the space between them and drawing oil from the suction port (this is the suction chamber). On the left side of the figure, the vanes 3 are gradually pressed into the slots by the inner wall of the stator, decreasing the working space and forcing oil out from the pressure port (this is the pressure chamber).

Single-Acting Vane Pump

Double-Acting Vane Pump

The working principle of a double-acting vane pump is shown in the figure. The stator’s inner surface is approximately elliptical. Rotor 1 and stator 4 are concentrically mounted, with two suction zones and two pressure zones symmetrically arranged. Rotor 1 completes two suction and pressure cycles per revolution. Most double-acting vane pumps are fixed-displacement pumps. While vane pumps have a more complex structure than gear pumps, they offer higher operating pressures, smaller flow pulsations, smoother operation, lower noise, and longer service life. Therefore, they are widely used in medium- and low-pressure hydraulic systems in specialized machine tools and automated production lines in machinery manufacturing. However, their complex structure results in less desirable suction characteristics and greater sensitivity to oil contamination.

Double-Acting Vane Pump