Let’s talk about a hydrogen filling machine

Hydrogen energy is a rich, green, low-carbon, and widely used secondary energy source, which is of great significance in reducing greenhouse gas emissions such as carbon dioxide and achieving the “dual carbon” goal. Accelerating the development of the hydrogen energy industry and laying out the development of the whole hydrogen energy industry chain is an important path to help China achieve the “dual carbon” goal, which will inject new momentum into the high-quality development of China’s economy. As an important facility at the hydrogen energy filling end, the construction speed of hydrogen filling stations has been accelerating in recent years. The hydrogen filling machine is one of the core pieces of equipment of the hydrogen filling station. Product development needs to comprehensively consider safety and other requirements and standards on the basis of the development of the filling protocol.

hydrogen filling machine

The basic functions of the hydrogen filling machine are gas filling and metering functions; that is, while filling the medium into the on-board storage tank, the unit price, gas filling volume, amount, etc. should be displayed. In terms of appearance, the hydrogen filling machine is generally composed of a rack, a display panel, a pressure gauge, a wire clamp, a hose, and an air gun. The metering function of the hydrogenation machine is generally completed by a mass flow meter. To realize the hydrogenation function, an explosion-proof solenoid valve, a pneumatic ball valve, a leakage alarm, an anti-overcharge system, and a control system with a controller and a display. Depending on the filling object, the hydrogen filling machine can be equipped with different specifications of hydrogen filling guns. The maximum filling flow rate is 2kg/min and 5kg/min respectively. It takes about 3-5 minutes to fill a car, and about 10-15 minutes to fill a bus.

The hydrogen filling machine is mainly composed of the following core components:

High-pressure hydrogen pipeline:

This is the channel for the hydrogen tank to transport hydrogen, ensuring that hydrogen can be safely transported from the gas source to the automobile hydrogen storage cylinder.

Safety valve:

The safety valve is one of the most critical safety components of the hydrogenation device of the hydrogen filling station. Its function is to prevent the internal air pressure of the hydrogen filling device from being too high and to turn on automatically after exceeding the specified range to ensure the safety of the hydrogen filling station. Due to the flammable and explosive characteristics of hydrogen, the choice and use of safety valves are very important. Qualified safety valves should be strictly tested and certified, such as American CSA, Chinese CCF, European Union PED, and other certifications.

Safety valve

Hydrogen detection and alarm device:

A hydrogen detection alarm device should be set up in the hydrogen accumulation area inside the hydrogen filling machine. When the hydrogen leakage reaches 0.4% in the air (10% LEL), an alarm signal should be sent to the control system in the hydrogen filling station. When the hydrogen leakage reaches 1.6% (40% LEL) in the air, an alarm signal should be sent to the hydrogen filling station. The control system sends a shutdown signal and automatically closes the valve to stop the gas.

Emergency stop button:

An emergency stop button should be installed on the hydrogen filling machine. When the button is pressed in an emergency, the valve should be closed, the gas filling should be stopped, and a stop signal should be sent to the control system in the hydrogen filling station.

Pull-off valve:

The pull-off valve is automatically divided into two parts under the action of an external force, which can be reconnected to ensure the continued normal operation of the hydrogen filling machine. This is a safety protection measure that can quickly cut off hydrogen sources in an emergency.

Pull-off valve

Hydrogenation gun:

The hydrogen gun should be able to match the hydrogen port of the filled vehicle well, with a reliable connection and no leakage. The design of the hydrogen gun should ensure that it can only be connected to the hydrogen filling port with a higher working pressure level, and avoid connecting it to the hydrogen filling port with a lower working pressure level.

These attachments ensure the safety of hydrogenation and prevent accidents by filtering impurities, controlling flow, emergency cutting, and other measures.