What is a tank volume chart for a liquid level gauge?
The core parameters of a volume chart are the tank’s liquid level height and the corresponding liquid volume.
Volume charts are utilized for calculating the capacity of irregularly shaped vessels.
When the tank height equals a certain height in the table, it means the current oil volume in the tank equals the liquid volume corresponding to that height in the table.
Bluesky liquid level gauges employ magnetostrictive probes, offering high measurement accuracy (±1 mm) and the capability to detect liquid interfaces (e.g., oil/water).

Why is a tank capacity table necessary?
There are several reasons, including: the irregular shape of oil tanks, and the potential deformation of underground tanks during transportation and burial; the presence of inlet pipes, manholes, and other structures within the tank; and the space occupied by sump pits at the bottom of the tank. These factors mean that the internal volume of the oil tank cannot be calculated using a fixed formula and must be calculated using an accurately measured tank capacity table provided by the manufacturer.
The image below shows the design of the tank capacity table settings interface for our company’s level gauge. As you can see, this level gauge allows for individual settings of the tank capacity table data for any oil tank. Individual data can be modified, and tank capacity tables can be imported and exported simply by inserting a USB drive.

Furthermore, settings can also be modified in a PC browser, as shown below:

False Losses Caused by Inaccurate Tank Capacity Tables
Inaccurate volume tables on horizontal tanks, or tilting or deformation of horizontal tanks after burial, will cause inaccurate inventory data. Tilting, in particular, can produce very large measurement errors, leading to false gains or losses. For example, with a 50m3 horizontal tank, if the oil level is 40%–60% of the diameter, a 0.6% can result in a calculated error of 400–500L.
Current period loss = (Beginning inventory – △1) + Current period deliveries – Current period sales – (Ending inventory – △2) = Current period loss – (△1 – △2)
Currently, there are three main methods for tank volume gauge calibration: on-site calibration using a standard tank, on-site calibration using a flow meter, and remote automatic tank calibration using a level gauge. Utilizing intelligent level gauges for remote automatic tank calibration has become the preferred method for gas station owners.