One control of six devices at the gas station

1. Product Description

The purpose of this manual is to introduce the operation and settings of the one control of six simple consoles.

The main functions of the console are:

1) remote authorization;

2) remote preset;

3) remote monitoring of refueling data;

4) remote modification of unit price function, which can control 6 refueling nozzles and requires the refueling machine to have the Bluesky communication protocol.

Console appearance:

Console appearance

2 Electrical connections

Power connection

1) Console power supply: DC7.5V

2) Console communication line: RS485

Console communication line

3. Operation method

Console keyboard display format:

3.1 Filling operation
Any filling

Operation steps:

1) Press [→] to select the address code;

2) Press [START] to confirm authorization, and the status prompt is Wait;

3) The fuel dispenser starts filling with the gun, and the console display shows the current filling amount, filling liters, and unit price in real-time, and the status prompt is Ing.

4) The fuel dispenser stops filling after the gun is hung, and the console status prompt is Free.

Preset liter filling

Operation steps:

1) Press [→] to select the address code;

2) Press [P/L] to select the preset liter filling mode;

3) Enter the number of liters to be preset;

4) Press [START] to confirm authorization, and the status prompt is Wait;

5) The fuel dispenser starts filling with the gun, and the console display shows the current filling amount, filling liters, and unit price in real-time, and the status prompt is Ing.

6) When the preset value is reached, the fuel machine stops filling, and the console prompts End. After the fuel machine hangs the gun, it prompts Free.

Note: Both the console and the oil engine have preset values, and the preset value on the oil engine is inaccurate.

Preset amount filling

Operation steps:

1) Press [→] to select the address code;

2) Press [P/L] to select the filling mode of the preset amount P;

3) Enter the amount to be preset;

4) Press [START] to confirm authorization, and the status prompt is Wait;

5) The fuel dispenser starts filling with the gun, and the console display shows the current filling amount, number of liters, and unit price in real-time, and the status prompt is Ing.

6) When the preset value is reached, the oil engine stops filling, the console prompts End, and the oil engine prompts Free after the gun is hung.

Note: Both the console and the oil engine have preset values, and the preset value on the oil engine is inaccurate.

3.2 Display screen settings

The console can choose an 886 display screen or a 664 display screen.

Operation steps:

1) Press the [*] key to enter the settings.

2) Select the first item LCDTyp, and press ENTER to enter the modification.

3) Press the ↑ ↓ keys to switch 886 or 664.

4) Press the ENTER key to modify.

5) Press the EXIT key to exit.

The console can choose 886 display screen or 664 display screen

3.3 Display screen decimal place setting

The console can set the decimal place of the amount, liters, and unit price according to the customer’s on-site needs.

Operation steps:

1) Press the [*] key to enter the settings.

2) Select the second item DEC, and press ENTER to enter the modification.

3) Enter the decimal place (0-4, amount, liters, unit price).

4) Press the ENTER key to modify.

5) Press the EXIT key to exit.

6) Check the screen, preset, and change the decimal place of the unit price.

3.4 Unit price setting

The console can remotely modify the unit price of the oil engine.

Operation steps:

1) Press the [*] key to enter the settings.

2) Select the third item Price and press ENTER to enter the modification.

3) Enter the unit price to be modified.

4) Press ENTER to modify.

5) Press EXIT to exit.

6) Check the unit price on the screen and the unit price modification interface to see if it has been modified.

3.5 Control the number of nozzles

The console can control 1-6 nozzles.

Operation steps:

1) Press the [*] key to enter the settings.

2) Select the fourth item GunNum and press ENTER to enter the modification.

3) Enter the number of guns (1-6).

4) Press ENTER to modify.

5) Press EXIT to exit.

6) Check the number of nozzles on the keyboard.

Note: The nozzle address starts from 1.