The overall R&D goal of domestic LNG submersible pumps is to develop a series of large-flow LNG cryogenic pumps (including in-tank pumps and high-pressure external transmission pumps), with technical level and operational reliability reaching the same level as international similar specifications, to meet the application needs of domestic large-scale LNG receiving stations and LNG plants.

The main research and development needs are in the following aspects:
(1) Pump hydraulic technology
Research and develop impeller types with high flow, efficiency, and low cavitation performance suitable for the physical properties of LNG. At the same time, further optimize the hydraulic design to ensure that the hydraulic curve of the domestic pump type is similar to that of the imported pump type, and ensure the stability of parallel operation in the existing device.
Optimize the speed and pressure distribution of the pump flow components, improve rotor dynamic balancing accuracy, pump installation accuracy, and component stiffness, thereby meeting the requirements of reducing pump group vibration and ensuring long-term pump group operation.
In order to ensure that all downstream equipment is not over-pressurized, the pump’s closing point head is required to be optimized and controlled. After the hydraulic design is completed, a CFD simulation is performed using relevant software. The diameter of the blades is modified to ensure that the head at the closing point is within the specified value range. Secondly, during the performance test, the impeller can be optimized based on the test data.

(2) Supporting research and development of the bottom valve of the tank pump
The reliability of the bottom valve of the tank pump will affect the safety of the pump. On the premise of completing the supporting research and development of the bottom valve of the imported pump, the domestic bottom valve is optimized and designed to meet the development and design requirements in terms of sealing, strength, interchangeability, and versatility. At present, in large-scale energy projects such as LNG receiving stations and LNG urban peak-shaving projects that have been put into operation in China, the replacement, interchangeability, and universality of the bottom valve systems of internationally renowned brands such as NIKKISO, EBARA, and CROYOSTAR have been achieved.
(3) Research on low-temperature resistant materials
The submersible pump is immersed in low-temperature LNG liquid. The pump part usually uses 316 stainless steel and aluminum alloy. How to ensure the strength and toughness of the material at low temperatures and the influence of temperature field changes on deformation needs further research.
Research on low-temperature motor materials is basically blank in China. There are some research reports on the state of motor materials at a working temperature of -160°C abroad; however, there is no established material selection standard. In order to solve the material selection problem of LNG pump low-temperature motor, a large number of low-temperature tests should be carried out on the materials constituting the motor to find materials suitable for LNG pump low-temperature motors and summarize the corresponding material selection principles.
Cables in low-temperature environments need to have materials that are resistant to low temperatures and maintain sufficient elasticity and toughness, as well as electrical conductivity and insulation properties. There is also a lot of research work to be carried out.

(4) Low-temperature motors
Under the influence of low temperature, the mechanical characteristics of the motor will also change. Research on the low-temperature mechanical characteristics of the motor and understanding the differences between the starting characteristics and operation of the motor under different working conditions at low temperatures and the normal temperature motor are of vital importance to the design and application of low-temperature motors.
(5) LNG medium lubricated bearings
For specific types of LNG submersible pumps, bearings must be lubricated with medium, that is, low-temperature LNG at -162°C is used as lubricant flushing for bearings to avoid local heating caused by long-term operation and bearing failure. Due to the low viscosity and poor lubricity of LNG itself, the design and manufacturing requirements for bearings are very high. At present, foreign bearing products are widely used in China. Since low-temperature LNG is in a saturated state, heat will be generated during the rotation and friction of the bearings, resulting in local LNG vaporization. If the vaporization is too large, it will affect the pump’s transportation performance. The research on bearing lubrication and cooling in low-temperature and low-viscosity environments is also a difficult problem that must be faced in the domestic development of LNG pumps.