In recent years, new energy gasoline and ethanol gasoline have been promoted. When ethanol is at high temperature, it evaporates more seriously. In severe cases, the self-priming pump cannot pump gasoline, and there is too much gas in the pipeline. How can gas stations improve this problem? There are several ways to improve it:

Optimize equipment installation and pipeline design:
The theoretical suction range of the self-priming pump is limited by atmospheric pressure (about 10.3 meters under standard atmospheric pressure), but it is affected by pipeline resistance and liquid gasification. It is recommended to install it at a height of ≤5 meters and as close to the oil storage tank as possible (horizontal distance <10 meters) to shorten the oil suction path.
Pipeline insulation and slope design:
The oil suction pipeline is wrapped with rubber and plastic insulation cotton (thermal conductivity <0.034W/m・K) or aluminum foil insulation layer to avoid direct sunlight and environmental heat conduction, so that the oil temperature in the pipe is controlled below 40°C (actual measurements show that the oil temperature of uninsulated pipelines may be 10~15°C higher than the ambient temperature).
Slope requirements:
The oil suction pipeline maintains a slope of 1%~2% toward the pump to avoid “air pockets” (gas accumulation in low-lying areas of the pipeline) and reduce the number of 90° elbows (resistance increases by 10%~15% for each additional elbow).
Control fuel temperature and vapor pressure:
The thickness of the soil covering the underground oil storage tank is ≥0.5 meters, or a spray water pipe is laid on the top of the tank (regular water spraying during high temperature periods in summer can reduce the oil temperature in the tank by 5~8°C).

Shading and ventilation:
A sunshade is set up for the above-ground oil tank, and an axial flow fan is installed around it for forced ventilation to reduce the ambient temperature around the tank.
Reduce oil tank breathing loss:
Install a breathing valve (set pressure ±2kPa) and an oil and gas recovery system to prevent the oil tank from frequently inhaling air due to temperature changes and reduce the volatilization of oil products caused by air entering.
Equipment selection and structural improvement:
Replace the traditional self-priming pump with a centrifugal tanker pump + vacuum auxiliary system, and accelerate oil extraction by pre-vacuuming (for example, a certain brand of V series self-priming pump is equipped with a gas-liquid separation tank, which can start normally at an oil temperature of 40°C).
Heat-resistant material pump body:
The pump body is made of cast iron + fluororubber seals (temperature resistance ≥120°C) to avoid deformation and leakage of seals at high temperatures. At the same time, the impeller is made of stainless steel to reduce frictional heat.

Install a gas-liquid separation device:
Install a gas-liquid separator (such as a cyclone separator) at the front end of the oil suction pipeline to separate the gasified oil and gas and discharge it through the exhaust pipe to ensure that the gas content of the fuel entering the pump body is less than 1%.
Replacement of seals:
Check the oil suction pipeline interface and the pump body seal ring every quarter. If aging (such as hardening, cracks) is found, replace it with nitrile rubber (NBR-70) or fluororubber (FKM) immediately to prevent air infiltration.