Solutions for Fuel Dispenser Malfunctions

As a piece of mechanical equipment, a fuel dispenser may exhibit operational irregularities if used improperly or poorly maintained. Should you encounter any of the following issues or malfunctions, please refer to the corresponding troubleshooting steps to address them; doing so will help improve operational efficiency and minimize potential losses. Below are solutions for fuel dispenser malfunctions.

Bluesky fuel dispenser

Fuel Dispenser Fails to Start or Starts Intermittently

  • After returning the nozzle to its holster, check if the keypad responds. If there is no response, verify that the power supply is functioning correctly.
  • Ensure the shift/operation lock is in the “on” position; the keyhole should be aligned with the red dot.
  • The fuel dispenser features a time-delay function; an interval of 2 to 4 seconds is required between shutting down and restarting the unit.

Failure to Start in “Preset Quantity” Mode

  • This may occur if the preset quantity is set to less than 1 liter. Try entering a larger quantity or selecting the “non-preset” (manual) fueling mode.
  • If a function key, such as the one for unit price, is pressed before entering the preset value, the input will not be registered as a preset quantity, effectively defaulting to a non-preset fueling operation.

Fluctuating Flow Rate

Air leaks in the piping, or the fuel level being too close to the foot valve, can cause large amounts of air to enter the system, resulting in an unstable (fluctuating) flow rate.

  • Open the triangular connecting flange; if the liquid level in the pipe drops, it indicates a leak in the foot valve or the piping. Repair the foot valve or the piping.
  • If the fuel level in the tank is too close to the foot valve, the pump may draw in large amounts of air; increase the fuel level in the tank.
  • If the foot valve is not operating smoothly, remove and clean it.
  • The temperature is too high, either because the piping is buried too shallowly or the fuel dispenser and piping are exposed to direct sunlight, causing significant fuel vaporization. Improve the fuel station’s piping system.
  • The piping has an inverted “U” (or “arch”) shape, or the pipes are sloped toward the fuel dispenser; improve the fuel station’s piping system.

Fuel Leakage from the Fuel Dispenser Exhaust Vent

Fuel leaks when the unit is idle (not dispensing) or at the moment of starting/stopping:

  • The temperature is too high, due to shallowly buried piping or direct sunlight on the dispenser/piping, causing the fuel to expand and leak. Improve the fuel station’s piping system.
  • Two pumps share a single fuel supply line, and the pump that is not in use leaks fuel. Improve the fuel station’s piping system.
  • Fuel leaks when the unit is left on for an extended period without dispensing, or after repeated start-stop cycles without dispensing; ensure operation strictly follows the user manual.
  • Air leaks in the piping can cause a mixture of fuel and air to be expelled from the exhaust vent during dispensing; repair the piping.
  • The float is stuck, preventing fuel from returning from the atmospheric pressure chamber; this can cause fuel to be expelled from the exhaust vent during dispensing. Repair or replace the float.

Inaccurate Totalizer Readings

  • Air has entered the system; check the pump, piping, and all connections for leaks.
  • The flow meter has corroded, leading to abnormal wear; remove any water from the piping or replace the rusted components.
  • Impurities in the fuel: Inspect the moving parts and friction surfaces of the flow meter; replace or refinish any components showing signs of wear.
  • Worn distribution valve: Replace the worn parts.
  • Leakage at the piston seal: Replace the piston.
  • Damaged O-ring: Replace the O-ring.
  • Debris on the sealing surfaces between the distribution valve and the base: Clean these sealing surfaces.
  • If a component cannot be repaired, replace the flow meter.

Under-dispensing (Insufficient Fuel Delivery)

Air entering the fuel supply line, or the liquid level in the tank dropping to the same height as the foot valve, can cause a large volume of air to enter the dispenser. If this air is not fully separated, it will be discharged in significant quantities through the air vent pipe. Repair the piping or increase the liquid level in the tank.

Over-dispensing (Excessive Fuel Delivery)

The connection between the flow meter and the encoder is faulty, or the encoder itself is damaged.

Slow Fuel Delivery

If the flow rate decreases during operation, investigate the following potential causes:

  • Clogged foot valve or pump filter: Remove and clean.
  • Worn rotor vanes: Replace the vanes (applies to vane-type combination pumps).
  • Low fuel level (causing excessive resistance): Increase the fuel level.
  • High temperature (e.g., shallowly buried piping, direct sunlight on the dispenser or pipes, or significant fuel vaporization): Improve the fuel station’s piping system.
  • Obstruction in the fuel line between the pump outlet and the nozzle: Remove any debris or replace the affected components.
  • Slipping V-belt: Tighten or replace the V-belt.

Abnormal Pump Noise

  • Clogged pump filter: Clean the filter.
  • Broken vanes: Replace the vanes (applies to vane-type combination pumps).
  • Malfunctioning overflow valve: Clean, reinstall, and adjust the valve.
  • Fluctuating pump noise (varying in intensity): Follow the troubleshooting steps for “fluctuating flow rate” (see below).
  • Poor connection between the motor and the pump; readjustment is required.
  • Foreign matter inside the pump; it must be cleared promptly.
  • Pump pressure is set too high.

Pump Seizure (Jamming)

  • Vanes are not moving freely; replace the vanes. (Vane-type pump)
  • Foreign matter inside the pump core; stop the unit immediately and remove the foreign matter. (Vane-type pump)
  • Seizure due to heat from dry friction (prolonged operation without drawing fluid is prohibited); stop the unit immediately, allow it to cool, reassemble the pump core, or replace it if damaged. (Gear-type pump)

Submersible pump type

Oil Leakage at Gaskets/Seals

  • Gaskets or O-rings are swollen or damaged; replace them and apply grease to the O-rings.
  • Bolts are not tightened sufficiently or have loosened due to vibration; tighten the bolts.

Failure of Single-Phase Motor to Start

Single-phase motors have high starting currents and limited tolerance for power supply fluctuations. If the supply voltage is too low or unstable, or if the wire gauge is too small (it should be at least 2.5 mm2 copper wire), excessive line loss may occur. These conditions can prevent a single-phase motor from starting, or cause it to malfunction after starting, which may easily lead to motor burnout. To ensure proper operation, it is essential to maintain a stable power supply and use wiring that meets the required specifications.

Vibration and Noise in the Flow Meter

  • Foreign matter on the bearings or connecting rods; disassemble the flow meter and remove the foreign matter.
  • Bearings are worn; replace the bearings.

Meter Advancing Without Fuel Delivery (Ghost Counting)

  • Fuel hoses have a degree of elasticity (expansion). When a long hose is used, it may expand the moment the pump starts, drawing in a small amount of fluid and causing the meter to register a count. Characteristic: The count value is generally consistent each time this occurs.
  • Leakage at the foot valve or in the piping. During the interval between two refueling operations, the fluid level in the piping gradually drops. When the next refueling begins, air enters the flow meter, causing it to rotate and register a count. The longer the interval between uses, the higher the count on the fuel-dispensing meter upon the next startup; additionally, gas is discharged when the fuel nozzle is opened. Please repair the foot valve or the piping.
  • The balancing valve is not sealing properly.
  • The piping has an inverted U-shaped (or “hump-shaped”) section, the foot valve is allowing fuel to flow back, or the piping has a leak, all of which cause the pump to draw in air. Please repair the piping.
Update cookies preferences