At present, many enterprises in my country have adopted oil and gas recovery systems to recover oil and gas from tank trucks, which effectively reduces the impact of oil and gas volatilization. However, in the process of using the oil and gas recovery system, certain losses will occur. Therefore, it is of great significance to study the influence of oil and gas recovery on fuel dispenser metering.

1. Working principle of oil and gas recovery system
The working principle of oil and gas recovery system is: the principle of oil and gas recovery system is an oil and gas recovery technology that integrates closed collection, efficient separation, and recycling. It means that during the production, storage, transportation, and sales process, oil and gas are collected from oil and gas storage tanks (tanks) or oil tank trucks (tank trucks), and transported to the oil and gas treatment system through closed pipelines. After purification, heating, adsorption, and other processes, the oil and gas are evaporated and discharged at low temperatures, or the heat is recovered for use in the process to meet the national emission standards.

2. The influence of oil and gas recovery system on fuel dispenser metering
2.1 The influence of oil and gas collection and storage on indication error
The oil and gas collector in the oil and gas recovery system has the functions of collecting, storing, and transporting oil and gas. During the refueling process, a small amount of gas will enter the refueling machine from the pipeline of the tanker. At the gas station, this part of the gas is not discharged directly, but after a certain treatment, it is stored in the refueling machine in a certain form. Since the gas is stored for a long time and the quality is uncertain, it will affect the flow and temperature of the refueling machine.
2.2 Impact of measurement environment
Due to the complex on-site environment of the gas station, the installation position of the refueling machine at some gas stations is relatively low, and there is a valve on the top of the fuel tank. If the refueling gun is directly aimed at the outlet of the fuel tank, it will affect the accuracy of the measurement result. Therefore, when measuring the refueling machine at the gas station, this environment should be avoided as much as possible, or a valve higher than the top of the fuel tank should be installed at the installation position of the refueling machine to reduce the impact of the environment on the refueling machine measurement.

2.3 Pipeline pressure change
The pipeline pressure of the oil and gas recovery pipeline is different from that of the refueling machine used for refueling. During the long-term use of the oil and gas recovery pipeline, due to the continuous consumption of the medium in the pipeline, some oil and gas will enter the flow meter through the small hole of the flow meter. In this case, although a stop valve is installed at the outlet pipe of the flow meter, due to the effect of the stop valve, a certain pressure difference is formed in the flow meter, which will cause inaccurate metering of the fuel dispenser.
3. Suggestions on preventing the gas station oil and gas recovery system from causing metering inaccuracy
3.1 Strengthen the periodic calibration and daily self-inspection management of fuel dispensers
Strengthen daily self-inspection management and regularly inspect fuel dispensers. Strictly abide by the safety operating procedures during the refueling process. Once an abnormal situation is found, it should be reported in time and the fuel dispenser should be stopped.
3.2 Promote the application of an online monitoring system for oil and gas recovery
Many gas stations usually only maintain and maintain the recovery equipment when performing oil and gas recovery, and do not pay enough attention to the monitoring and management of recovered oil and gas. Therefore, it is necessary to promote the application of online monitoring systems for oil and gas recovery. Compared with traditional manual detection methods, online monitoring systems for oil and gas recovery have the following advantages:
- Reduce the cost of manual detection.
- Improve the oil and gas recovery rate.
- Improve management efficiency.
- Realize refined management.
3.3 Strengthen the maintenance management of fuel dispensers
The fuel dispenser calibration cycle is generally once every six months. To extend the fuel dispenser calibration cycle and avoid inaccurate fuel dispenser metering, the following measures can be taken:
- Strengthen the training of fuel dispenser maintenance personnel.
- Enterprises should regularly calibrate fuel dispensers before putting them into use.
- Regularly inspect and maintain the oil and gas recovery system.
- Strengthen the management of fuel dispenser oil samples.