The shut-off valve is one of the core components of a fuel dispenser. Let’s take a look at its function!
Why install a shut-off valve?
Some gas station operators believe that installing a shut-off valve is unnecessary, and some simply install a simple ball valve as a substitute. Today, we will share why submersible pump dispensers need to be equipped with a shut-off valve.

As shown in the diagram, one submersible pump may simultaneously supply fuel to multiple fuel dispensers and nozzles. In terms of actual operation, the operation of the submersible pump is controlled by the nozzle switch of the machine it supplies; that is, opening any nozzle switch corresponding to the submersible pump will control the submersible pump to start supplying fuel.
Design and Construction Specifications for Gas and Gas Filling Stations
Submersible pump refueling dispensers should have a shear valve installed on the fuel supply pipeline at their bottom. When the fuel dispenser is impacted or catches fire, the shear valve should automatically close.

Technical Parameters:
- Oil Pressure Test: The shut-off valve does not leak under a 1.4MPa oil pressure test.
- Shut-off Test: The valve breaks under a bending moment of 350N•m~880N•m, and there is no leakage at the valve port after breakage, meeting the shut-off requirements.
- Fusion Test: At 76°C on the boom, the emergency shut-off valve automatically closes, and there is no leakage at the valve port after closure, meeting fire protection requirements.
- By operating medium: Divided into liquid shut-off valves and oil/gas recovery shut-off valves;
- By structure: Type 1 Normal refueling (main valve, temperature switch, check valve, and pressure relief valve), Type 2 Disconnect moment (main valve and temperature switch), and Type 3 Automatic shutdown (main valve);

- Note: Type 1 and Type 2 shut-off valves are used in liquid pressure systems, while Type 3 shut-off valves are only used in oil/gas systems.
- Currently, commonly used liquid emergency shut-off valves for fuel dispensers have 1.5-inch internal threads at both ends.
Key points for shut-off valve use:
- The pipe threads at both the inlet and outlet ends of the valve must be sealed with oil-resistant pipe thread sealant. PTFE tape (Teflon tape) is strictly prohibited.
- The on-site foundation must be constructed according to the corresponding equipment foundation construction drawings to ensure a reliable fixing position for the shut-off valve.
- The anchoring device (for fixing the shear valve) must be able to withstand a force greater than 650 ft-pounds (900 N·m) on each valve.
- When the valve needs to be opened, rotate the lever counterclockwise to lift the connecting rod, allowing the pin on the lever to slide into the groove of the connecting rod. The lever is then fixed in place, keeping the valve in the fully open position. To close the valve, rotate the lever counterclockwise slightly to push the connecting rod open. The lever will automatically spring back clockwise and close the valve.
- During maintenance of the fuel dispenser’s hydraulic system or cleaning (replacing) of the fuel dispenser’s filter, this valve can be closed to cut off the fuel inlet pipe, preventing the risk of fuel spraying during maintenance.