In flammable and explosive environments such as fuel dispensers and gas dispensers, the stable operation of equipment not only affects efficiency but also directly affects safety. As the core method of data transmission between devices, the isolated communication design of RS-485 communication is particularly important.
Three fatal risks of non-isolation
Static electricity and surge directly hit the core circuit.
Oil machine equipment is exposed to the outdoors all year round. Electromagnetic pulses in thunderstorms and friction static electricity during refueling may enter the control board through the 485 bus. Without isolation protection, an instantaneous high voltage will directly burn the chip, causing metering out of control or shutdown, and may even cause sparks in explosion-proof areas.

Ground potential difference causes communication disorders.
When multiple devices are connected, the difference in ground resistance of different housings will form a ground potential difference. The non-isolated RS-485 bus will become a current channel, which may cause data packet loss and inaccurate measurement at the least, or even cause the entire communication network to be paralyzed, causing disputes in trade settlement.
Cross-interference poses a safety hazard.
There are both strong current circuits (such as motors) and weak current signals (such as flow sensors) inside the fuel dispenser, and the unisolated bus will become a bridge for interference transmission. When strong current interference penetrates into the weak current system, it may cause malfunctions – for example, it continues to operate when the fuel supply should be stopped, causing fuel overflow.
How to choose a reliable isolation solution?
There are currently two mainstream RS-485 communication isolation solutions:
- Photoelectric isolation: Data is transmitted through optical signals to achieve complete electrical isolation, which is suitable for high-frequency communication scenarios.

- Magnetic isolation: Using the principle of electromagnetic induction, it has stronger anti-interference ability and is more stable in strong electromagnetic environments (such as near gas stations).
Regardless of the solution, the core is to ensure that the insulation resistance between the bus and the control circuit is ≥100MΩ and the withstand voltage is ≥2.5kV to meet the safety standards of explosion-proof areas.
Isolation is not an optional configuration, but a bottom-line requirement.
In special places such as gas stations and gas stations, RS-485 communication isolation is not an “optimization item”, but a hard indicator that must be met. The small isolation module blocks fatal risks and ensures the life of equipment and personnel safety.