The accuracy of a fuel dispenser is an important criterion for measuring the quality of a gas station, but the accuracy of a fuel dispenser is not static. As the usage time increases, the accuracy of the fuel dispenser will also change. This is because as the dispenser ages, the error of the flow meter changes. This blog will explore why fuel dispenser accuracy changes over time and what solutions are recommended.

1. Why does the accuracy of the fuel dispenser change?
This is because every time the gas pump is working, the piston inside the flow meter responsible for measuring the flow rubs against the metering chamber. As the gas pump’s working time increases, excessive wear will cause this gap to increase, and the error will also increase accordingly.
2. Method for correcting the accuracy of the fuel dispenser
If the inaccurate measurement is caused by the large internal gap of the flow meter, we usually recommend that the gas station adjust the small piston on the flow meter to correct the accuracy. However, if the reason for the inaccurate metering is that the fuel dispenser has been in use for too long, thus exceeding the service life of the flow meter, then no matter how the small adjustment piston on the flow meter is adjusted, there is no way to solve the error problem.
At this time, we need to consider whether the flow meter has exceeded its service life. Usually, the service life of a metal piston flow meter is about 3 to 5 years, but the actual service life will be affected by the actual usage (oil sales volume) and the different oil products.
For example, if the oil used at a gas station is diesel because diesel itself has a certain lubricating effect and high viscosity, the service life of the flow meter using diesel is more than 5 years. However, if the oil used is gasoline, since gasoline itself has no lubricating effect, the piston and the metering chamber will be worn out, resulting in increased leakage flow. Therefore, the service life of the flow meter used for gasoline is generally 3 to 4 years.

3. Check whether the flow meter has reached its service life
If you want to measure whether your flow meter has reached its service life, you can use the following method to determine it. First, you need to use a large flow rate to test the flow meter. Perhaps the measurement result is qualified, but when you switch to a small flow cumulative measurement, the measurement result shows a serious error. Then you need to try to adjust the flow meter piston and replace the connection block in the flow meter. If the measurement results are still the same as before, you need to check the gap between the piston and the metering chamber. If it is found that there is no friction between the piston and the metering chamber, it can be determined that the flow meter has reached the end of its service life. The problem with such a fuel dispenser must be solved by replacing the flow meter.

4. Special solutions
If you are unable to replace the flow meter in time due to various reasons, and you want to continue operating but do not want to suffer losses due to the error of the flow meter, you can take emergency measures.
Temporarily swap the diesel meter with the gasoline meter until your new meter is ready. The reason for this is that the flow meter for diesel is less prone to wear, so when you use a flow meter that was originally designed for diesel to add gasoline, the error will be smaller; When the flow meter used for adding gasoline is used to add diesel, although the flow meter is more worn, fortunately, the high viscosity of diesel will also reduce the error. This method can be used for a short time, but it cannot fundamentally solve the problem.
There is another situation, that is, the solenoid valve on some gas pumps is broken, or the early gas pumps were not equipped with solenoid valves. This is relatively simple, just replace and install a new solenoid valve.
5. Summary and suggestions
To sum up, as the fuel dispenser ages, its accuracy will be affected, mostly due to the flow meter and solenoid valve. By replacing or repairing these two aspects, the problem of large flow meter measurement errors can be solved. At the same time, gas stations should pay attention to the daily maintenance and upkeep of equipment, and reasonably arrange the working hours of gas dispensers. For gas stations, choosing high-quality gas dispensers and parts is also an important guarantee of the long-term stability of equipment operation.