Hydraulic CNG Compressor Working Principle
1. Gas Intake and Compressor Control
The gas delivered by the tank truck enters the compressor through the gas unloading column. When the gas pressure in the gas cylinder group is higher than the starting set value, the compressor does not start. However, when the pressure in the gas cylinder group falls below the set value, motors A and B drive the oil pump, supplying oil to the hydraulic system. The PLC control system manages the reversing valve to direct oil to either the upper or lower end of the oil cylinder.
2. Piston Movement and Air Intake
When oil enters the upper end of the oil cylinder, the piston moves downward. Since the piston rod is connected to two cylinder pistons, both pistons at the ends of the rod move downward. The first compression chamber of the upper cylinder and the second compression chamber of the lower cylinder begin to intake air. In comparison, the second chamber of the upper cylinder and the first chamber of the lower cylinder expel air.
3. Reversal and Continuous Compression
As the piston reaches the reversing position, a position sensor in the upper chamber sends a signal to the PLC. The PLC then stops supplying oil to the upper end of the cylinder and directs oil to the lower end, causing the piston to move upward. This switch in piston movement reverses the chamber functions, enabling continuous intake and exhaust as part of the reciprocating motion.
4. Exhaust and Gas Cooling
When the gas is compressed to a pressure higher than that in the cylinder, it is exhausted through the external pipeline. The exhaust pipe is connected to a gas heat exchanger, and after cooling, it supplies high-pressure gas to both the high-pressure cylinder and the gas dispenser. Once the high-pressure cylinder reaches a certain threshold, the sequence valve opens, allowing gas to enter the medium-pressure cylinder and provide medium-pressure gas to the dispenser.
5. Hydraulic Compression and Gas Distribution
The gas compression system uses a hydraulic cylinder to convert hydraulic energy into kinetic energy to drive the pistons. If the gas pressure in the cylinder is below the external pipeline pressure, compression continues. Once it exceeds the external pressure, gas is expelled via a one-way valve to external gas storage or a filling machine. With inlet and outlet valves at both ends of the cylinder, gas continuously flows in from the air intake pipe, is compressed, and exits through the exhaust pipe. The one-way valves ensure proper intake and exhaust flow.

Introduction to the filling process of hydraulic CNG compressor
1. Introduction to Hydraulic Reciprocating Natural Gas Compressors
Hydraulic reciprocating natural gas compressors are primarily used in natural gas daughter stations. Natural gas from the tank truck is split into two routes outside the compressor. One route goes directly into the low-pressure pipeline of the gas vending machine, while the other enters the compressor through the low-pressure pipeline (inlet interface). The compressor’s medium-pressure outlet connects to the station’s gas cylinder group and the medium-pressure pipeline of the vending machine. The high-pressure outlet connects directly to the high-pressure pipeline of the vending machine.
2. Refueling Process
During refueling, natural gas from the tank truck first flows through the low-pressure pipeline to the gas vending machine. If the pressure drops below the required filling pressure, the medium-pressure gas from the cylinder group enters the vending machine. If the pressure remains insufficient, the compressor automatically starts and supplies gas through the high-pressure pipeline until the car’s required filling pressure is reached.

3. Post-Refueling Pressure Management
After refueling, the compressor monitors the medium-pressure system and gas cylinder group. If the gas cylinder pressure falls below the set value, the compressor automatically inflates the cylinders to the specified pressure and then stops, maintaining high pressure in the system.
4. Safety Features
The compressor is equipped with multiple protections:
- Minimum inlet pressure protection
- Maximum outlet pressure protection
- Automatic start and stop protection
- Automatic safety control system
The safety valve ensures that if system pressure exceeds the working limit, it releases excess gas, lowering the pressure to safe levels. This gas is vented to a safe location via steel pipes, as per safety regulations.
5. Soundproof Box and Additional Safety Measures
The compressor is housed in a soundproof box, which includes explosion-proof lighting and a gas concentration alarm. If the natural gas concentration becomes too high, the equipment will shut down and trigger an alarm. The soundproof box provides sound insulation, noise reduction, weather protection, and security. Heat dissipation shutters on the rear ensure proper ventilation, eliminating the need for a separate compressor room.